40 results (0,15834 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Exd Conventional Triple IR Flame Detector 55000-062APO

Apollo Exd Conventional Dual IR Flame Detector 55000-061APO

Apollo Mounting Plate for 1 Prism 8-50m 29600-530

Apollo XP95 Sounder Control Unit with Isolator - 55000-852APO

Apollo XP95 DIN-Rail Sounder Controller 5 Amperes 55000-182APO

Apollo XP95 DIN-Rail Sounder Controller 5 Amperes 55000-182APO

Please note This product currently has an extended leadtime due to a component shortage. Please contact us for further information.Apollo XP95 DIN-Rail Sounder Controller 5 Amperes 55000-182APOThe DIN-Rail Sounder Controller 5 Amperes is used to control the operation of a zone of externally powered sounders and report their status to the control panel.Electrical DescriptionThe DIN-rail Sounder Controller is loop powered and operates at 1728V DC. It requires a local power supply of 1235V DC to power the external load which may be up to 5A. A polarising diode is required with each alarm device as sounders are operated by voltage reversal provided by a double-pole change-over relay. The sounder circuit is protected by a fuse rated at 5A quick acting.OperationThe Sounder Controller allows sounders to be operated continuously or be pulsed 1 second on 1 second off. Sounders may be operated individually or in groups and whichever address mode has been applied may be synchronised when in pulsed operation. An opto-coupled input is provided to monitor the state of the external power supply. In normal operation the Sounder Controller returns a pre-set analogue value of 16 but in the event of an open or short-circuit fault or of a fault in the external power supply the unit returns a pre-set analogue value of 4.Key FeaturesAllows sounders to be operated continuously or be pulsed 1 second on 1 second offMay be synchronised with loop soundersAn opto-coupled input is provided to monitor the state of the external power supplyFeatures group addressingWill accept a load of up to 5A

GBP 97.03
1

Apollo I.S. Conventional Triple IR Flame Detector 55000-063APO

Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APO

Apollo 29600-446 Intrinsically Safe Sounder Visual Indicator

Apollo Conventional Triple IR Flame Detector 55000-019APO

Apollo Conventional Dual IR Flame Detector 55000-060APO

Apollo Conventional UV Dual IR Flame Detector 55000-064APO

Apollo SA4700-103APO Intelligent Mains Switching Input Output Unit

Apollo Series 65 Marine Mounting Base 45681-200MAR

Apollo XP95 Ancillary Base Sounder 45681-276APO

Apollo SA5501-320APO Open-Area VID White Body White Flash

Apollo SA4700-302APO Intelligent DIN-Rail Input Output Unit

Apollo Series 65 Standard Base - 45681-200APO

Apollo SA5501-321APO Open-Area VID White Body Red Flash

Apollo SA4700-300APO Intelligent DIN-Rail Switch Monitor

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60
1

Apollo Cat O. XP95 Sounder VAD Base with Isolator 45681-705APO

GBP 72.02
1

Apollo AlarmSense Open Area Sounder Beacon 55000-017APO

Apollo AlarmSense Open Area Sounder 55000-018APO

Apollo AlarmSense Open Area Sounder 55000-018APO

Apollo AlarmSense Open Area Sounder 55000-018APOThe AlarmSense open area sounder has an IP65 rating meaning that it is suitable for outdoor use. In the event of unauthorised sounder head removal the unit generates a fault warning but all other devices on the same zone will continue to operate.Brand InformationAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive.AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation.As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesAlarmSense sounders and manual call points are fitted to the same zone as detectors. In quiescent state the zone is powered at between 9V and 15V nominally 12V at which only detectors and call points operate. Sounders require 24V to operate.When an alarm is detected on a zone the control panel increases the line voltage to 24V on that zone causing the sounders to produce a continuous Evacuate sound. Any voltage-sensitive output devices - relay modules or other alarm devices - also operate.When the voltage is increased to 24V the detector alarm current will reduce to 1.5mA. The detectors are latched in alarm until they are reset by reducing the voltage to less than 2V for greater than 1 second. Output devices will de-activate each time the voltage is reduced to 12V unless otherwise stated in their specification.It is possible to generate an Alert tone by pulsing the supply voltage from 12V to 24V and the sounders configured to continuous output. Pulse frequency of 1 second on 1 second off is recommended for compliance with BS5839 Pt1.Key Features Sound output of up to 99dBLPCB approvedSeparate first-fix base for ease of installationIP65 rated outdoor useDesigned for use as part of an AlarmSense fire alarm panel systemWall mountedTone synchronisationMonitors the presence of the sounder head

GBP 40.24
1

Apollo SA4700-100APO Intelligent Switch Monitor