25 results (0,15368 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1771.76
1

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1539.52
1

Baldwin Boxall BDM400TSN Desk Mic for PCTSINT All Call Switch

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2The BS83002009 standard requires that all new disabled WC installations are fitted with an emergency assistance alarm. This Disabled WC Alarm Kit provides a compliant reliable and easy to use disabled persons toilet alarm which contains a controller ceiling pull switch reset point overdoor light.The Controller should be located so that it is easily seen heard by people able to give assistance indicates where help is required. The unit is not suitable for exterior location unless suitably protected against water ingress.The Ceiling Pull Switch must be located so that it can be operated from the WC and from an adjacent floor area. The Ceiling Pull Switch is supplied with two G pulls one should be set a height between 800 1000mm the other set 100mm above the floor level.The Overdoor Light Sounder should be located so that it is easily seen and heard by people able to give assistance and indicates where help is required. Normally above the door outside the WC.The Reset Point should be located inside the WC area so that it is reachable from both a wheelchair and the WC.Key FeaturesIntegral mains powered PSU.Relay Output option.BS83002009 Acknowledge Feature.Includes Backup Battery.Powerful LEDs Sounder.Supply Healthy LED.Reset Button EnableDisable.Self-Test Facility.Twin G-Pulls LED.Reset Point with Re-Assurance LED.Overdoor Light with Sounder.All components have a stainless-steel finish

GBP 701.27
1

Baldwin Boxall Omnicare Type B Stainless Steel Disabled Refuge Remote BVOCECPS

Baldwin Boxall Touch Screen Microphone BVRDTSM

Baldwin Boxall Touch Screen Microphone BVRDTSM

Baldwin Boxall Touch Screen Microphone BVRDTSMIntroducing the new EN54 certified touch screen control microphone a multi-function user interface for VIGIL voice alarm systems.The BVRDTSM is an easy to use microphone with a touch sensitive screen that provides full control of the voice alarm system. Special features include a Near Field Communication NFC smart card user access facility.The microphone is a stylish unit which has all the functions that you would expect from a voice alarm system control microphone. It provides the user with unique options such as connecting a third-party music feed directly to the microphone to broadcast to selected areas or zones.The unit has a dual output ability which provides the opportunity to route a broadcast via an alternative rack on the system ideal for sites where separate A and B circuit racks are required. Another feature is the hard-wired bypass input which enables an emergency all call announcement in the unlikely event of a processor failure.With straight-forward multi-page scroll through operation the microphone enables full control of a VIGIL voice alarm system including access allowingZone or all call selection.Live speech for general paging announcements.Emergency paging facility given highest priority on the system automatically overriding all other broadcasts.Select system stored messages general and critical with priority given to the most critical for broadcast to chosen zones.Operators can use the microphone to record non-critical messages and store them for future use.A third-party music audio feed can be connected to the microphone. The output can then be routed by the user to a single or combination of zones.Select and route background music for broadcast to individual or multiple zones.Volume adjustment function provides the ability to change the volume of non-critical broadcasts to selected zones.View detailed activity history and fault logs.Configurable group buttons enable selection of multiple zones by a single touch.Configurable function buttons enable automatic multiple message playback.Key FeaturesStylish easy-to-use control microphone with a capacitive touch bright seven-inch screen.Emergency control mode live emergency broadcasts from the unit will override messages triggered by the fire panel.Near Field Communications NFC for card or pin based operator log-in feature enabling access to a pre-determined level of control.Dual output facility providing the ability to route the broadcast via a different rack on the system for sites where separate AB circuit racks are required.A hard-wired bypass input enables an emergency all call announcement in the unlikely event of a processor failure. There is also an option to fit an emergency bypass all call switch to the microphone.Critical signal path monitoring of the system - all faults being visibly and audibly indicated at the microphone.Compatible with VIGIL2 and VIGIL3 all microphone configuration is performed via the touch screen.

GBP 1654.73
1

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSPThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1041.47
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCCThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 876.36
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCLThe combined unit for the Omnicare LOOP-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 886.33
1

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSLThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1071.41
1

Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP

Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP

Baldwin Boxall BVOCECP OmniCare Remote - Red

Baldwin Boxall BVOCTSHUB OmniCarePLUS Network Hub Req BY24 amp 2 x IF PH

Baldwin Boxall VIGIL2 Slave Router BVRD2SLT adds 6 Inputs 8 Outputs and 6 Messages

Baldwin Boxall VIGIL2 Slave Router BVRD2S adds 12 Inputs 16 Outputs and 12 Messages

Baldwin Boxall BVRDTSMS Vigil 3 Touchscreen Microphone Surface Mount

Baldwin Boxall BVRDTSMS Vigil 3 Touchscreen Microphone Surface Mount

Baldwin Boxall BVRDTSMS Vigil 3 Touchscreen Microphone Surface MountThe BVRDTSMS is the surface mountable version of our multi-function touch screen microphone for VIGIL voice alarm systems.An easy to use microphone with a touch sensitive screen that provides full control of the system.Key FeaturesRack mountable voice alarm control microphone for multiple zonesFist held microphone capsuleNear Field Communications NFC for card or PIN based operator log-in feature enabling access to a predetermined level of control.Operators can use the microphone to record non-critical messages and store them for future use.Stored messages can be scheduled for regulartimed broadcast by the operator.Straight-forward multi-page scroll through option providing full control of a VIGIL voice alarm system.Select system stored messages - general and critical with priority given to the most critical - for broadcast to chosen zones.Zone or all call selection.Live speech for general paging and emergency announcements.Select and route background music for broadcast to individual or multiple zones.Volume adjustment function provides the ability to change the volume of non-critical broadcasts to selected zones.Emergency control mode - live emergency broadcasts from the unit will override messages triggered by the fire panel.Emergency paging facility - can be given highest priority on the system automatically overriding all other broadcasts.Critical signal path monitoring of the system - faults being visibly and audibly indicated at the microphone.Detailed fault logs accessed via the touch screen.All microphone configuration performed via the touch screen.Compatible with VIGIL2 and VIGIL3 all microphone configuration is performed via the touch screen.

GBP 3108.07
1

Baldwin Boxall BVRDTSMR Vigil 3 Touchscreen Microphone Rack Mount

Baldwin Boxall BVRDTSMR Vigil 3 Touchscreen Microphone Rack Mount

Baldwin Boxall BVRDTSMR Vigil 3 Touchscreen Microphone Rack MountThe BVRDTSMR is the rack-mountable version of our multi-function touch screen microphone for VIGIL voice alarm systems.An easy to use microphone with a touch sensitive screen that provides full control of the system.Key FeaturesRack mountable voice alarm control microphone for multiple zonesFist held microphone capsuleNear Field Communications NFC for card or PIN based operator log-in feature enabling access to a predetermined level of control.Operators can use the microphone to record non-critical messages and store them for future use.Stored messages can be scheduled for regulartimed broadcast by the operator.Straight-forward multi-page scroll through option providing full control of a VIGIL voice alarm system.Select system stored messages - general and critical with priority given to the most critical - for broadcast to chosen zones.Zone or all call selection.Live speech for general paging and emergency announcements.Select and route background music for broadcast to individual or multiple zones.Volume adjustment function provides the ability to change the volume of non-critical broadcasts to selected zones.Emergency control mode - live emergency broadcasts from the unit will override messages triggered by the fire panel.Emergency paging facility - can be given highest priority on the system automatically overriding all other broadcasts.Critical signal path monitoring of the system - faults being visibly and audibly indicated at the microphone.Detailed fault logs accessed via the touch screen.All microphone configuration performed via the touch screen.Compatible with VIGIL2 and VIGIL3 all microphone configuration is performed via the touch screen.

GBP 2871.29
1

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMP

Baldwin Boxall VIGIL2 Power Supply with Dual Outputs BVSMPVIGIL2 voice alarm system power supplies employ switch mode techniques to improve efficiency and reduce unwanted heat dissipation and weight.Key FeaturesThe BVSMP has two individually protected outputs at 24V the BVSMPLT has one.Each BVSMP will drive either two BV225 two BV125D or two BV050Q.Each BVSMPLT will drive one BV225 one BV125D or one BV050Q.Provide independent power converters with current and overvoltage protection circuits.Continual monitoring of the charger and all DC outputs ensures reliability.Standby batteries are continually float charged by the unit. Ensuring that in the event of mains failure power is maintained.Built-in deep battery discharge cut off preventing total discharge that can destroy the standby batteries in the event of AC power failure for long periods.A protected output is provided to power a mixer or auxiliary circuits.In the event of a fault condition an internal relay releases providing a changeover contact. A fault will be indicated on the EVAS router.The constant voltage charger is set for the recommended float charge. Should the battery fall below this level the BVSMP will charge at a constant rate of three Amps progressively reducing once the battery has achieved its nominal float level.Outputs together with a volt-free fault changeover contact are provided by a nine-way crimp connector plug and socket.Several chargers may be paralleled when used for larger systems. Paralleled BVSMPs must be synchronised.

GBP 1243.78
1

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8Our telephone interface units enable staff to make public address announcements from their own desk telephone. The free-standing units act as an interface between the analogue telephone system and the amplifier.Key FeaturesOperated by simply dialling the BT5BT8 extension number.Each unit is supplied with an IEC mains lead.Can be used to broadcast live announcements.Additional facility enables the user to pre-record an announcement. This reduces the risk of feedback where the telephone is adjacent to a loudspeaker.When connected to a telephone system with MF signalling the BT8 enables the user to select up to eight zones via the telephone keypad.An internal selector determines if the recorded message is played once or twice.Can be wired into any two-wire analogue extension port via a designated master extension socket. Another option is to connect the unit to the paging port available on most modern telephone switches. However they are not designed to operate on keyphone system extension ports.Outputs are selectable from line or microphone level.Signal output and zone select connections are via a 25 way D connector.Compatible with our BDM300 range of desk microphones connected via the BMS25 socket box supplied with the microphone.We recommend using our B81R relay unit for the zone select switching.Please note the BT8 is not approved for direct connection to the BT network. Under general approval NSG23J100003 it may be connected to a port on a telephone switch PABX. This unit should only be used with a switchable amplifier input.

GBP 1050.54
1

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAMThe BVLAM provides 8 zone 100V line relay switching loudspeaker zone selection from 1 amplifier.It incorporates impedance monitoring on all 8 loudspeaker lines when the zone is not selected. If the load increases impedance decreases the appropriate fault LED illuminates steady and if the load decreases impedance increases the fault LED will flash.The impedance changes for a fault to be detected is selected to either 20 or 40 using the mode DIL switch 8. If the impedance falls to approximately 50 of its original value the line is considered to be short circuit and will not be selected to the amplifier.All 8 zone select inputs will access when it is between 2 to 6.5V. An open circuit access input above 15V will be indicated by the appropriate fault LED flashing and a short circuit access input below 2V by the fault LED illuminating steady.Under all fault conditions the OK LED will extinguish and the common fault relay volt-free contacts to change state.Key FeaturesRack-mountable unit 1U high. Two units can be mounted across one rack shelf.Provides eight loudspeaker zone selection from one amplifier.On receipt of a signal from an input ie zone selecting microphone the BVLAM triggers the amplifier to output to the selected zone.An internal relay enables zone switching.The BVLAM provides constant impedance monitoring on each of the eight loudspeaker circuits when not selected.LEDs are used to indicate a drop or increase in impedance - set at either 20 or 40 by DIL switches.Note due to detection accuracy BVLAM is only suitable for BS5839-8 voice alarm systems with less than five speakers per circuit.Access faults on any of the zones from the microphone are indicated by LEDs on the BVLAM.Additional LED indicators are provided to show system healthy and supply healthy.The Baldwin Boxall Impedance Monitor BVLAM provides a combination of zones relay switches from one amplifier. It changes if a fault is detected.

GBP 880.90
1