19 results (0,14467 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 576.440.015FC FC442AVB Addressable Open Class Base Sounder Beacon

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BCThe Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV has an outdoor version with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator15 selectable tones for FC440CAVBRealistic Conventional Bell Tone4 selectable volumes for FC440CAVB2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareMounting orientation CeilingIndoor type AOutdoor type B IndoorWeight g 178Housing colour ClearOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesVibration shock corrosion EMC Complies with EN54 series requirementsIngress protection rating IP21CFlash colour White

GBP 202.74
1

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 251.53
1

Fireclass FC440AIR Addressable Red Wall Sounder VID

Fireclass FC440AIW Addressable White Wall Sounder VID

Fireclass FC445AIR Addressable Weatherproof Red Wall Sounder VID

Fireclass FC440AVR Addressable Red Wall Sounder VAD

Fireclass FC445AVR Addressable Weatherproof Red Wall Sounder VAD

Fireclass FC440AVW Addressable White Wall Sounder VAD

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF ModuleThe MPM800 is used to provide various expansion capabilities via the remote bus RBUS. The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display LEDs key switch and keys on the OCM800 and the operator display module.The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 IO. The MPM800 also has a printer interface for connecting to a serial or parallel printer.An additional printer driver kit is required to allow the MPM800 to drive a printer - a serial isolation module should be used to eliminate earth fault indications caused by some mains connected printers.Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 including the main OCM800 user interface. One OCM800 can also be in the form of an emulated user interface on a remote PC connected via the network or dial up modem.The following IO and LED annunciator modules can be saved from an MPM800Up to 5 x IOB 800 8 in8 out expansion boardUp to 5 x XIOM 800 16 way universal IO boardOne Mimic Panel 80-way LED mimic driver PCBOne 80-way ANN 880 LED mimicOne 40-way ANN 840 LED mimic using red yellow LEDsTwo 20-way COM 820 LED statuscommand modulesThe MPM800 is mounted by plugging directly onto the back of those items markedKey FeaturesFeatures an XBUS whichcan be used to drive up to 80 IOPrinter interface for connecting to a serial or parallel printerDirect Interface to Zonal Displays and other ModulesInterfaces to FIM Board

GBP 230.37
1

Fireclass FC440AIB Addressable Base Sounder VID

Fireclass FC440SB Addressable Base Sounder

Fireclass 540.003.006FC 601RIL Remote Indication LED

Fireclass 516.800.908 801RIL Remote Indicator

Fireclass 568.800.034FC HVR800 High Voltage Relay Module In D800 Housing

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High PowerThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High. The High power option provides more coverage for the VAD compared to Standard.Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 146.15
1

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard PoThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High.The High-power option provides more coverage for the VAD compared to Standard. Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 107.70
1

Fireclass 517.050.023FC 5BEX 5 Universal Ex Detector Base

Fireclass 517.050.023FC 5BEX 5 Universal Ex Detector Base

Fireclass 517.050.023FC 5BEX 5 Universal Ex Detector BaseThe 517.050.023FC 5BEX detector base has been ATEX approved for use with the series M600Ex and series 800Ex intrinsically safe detectors and is covered by type examination certificates BAS01ATEX1134X3 and BAS01ATEX1194X3 respectively.The 5BEx 5 Universal Base is compatible with M600Ex MX 800Ex and the 800Exn ranges of Detectors. This document describes its use with the 800Exn series of detectors. Thus a ceiling-mounted detector comprises the specific detector type plus a 5BEx 5 Universal Base. The range is intended for two wire operation.When the detector is mounted on the base the detector LED provides a visual indication of its status through 360 degrees. The detector may be locked in position by inserting a locking key which is part of the detector moulding. This is broken from the sprue and inserted in the locking key slot.Key FeaturesHigh performanceDetector base is made of fire resistant FR110 BAYBLENDThe base can be used with the DHM-5BThe base accepts an address label carrier from the detector when it is fitted to the base. The base also has four electrical contacts which align with the contacts on the detector once the latter is fitted and fully latched into positionThe raised rib is aligned with a raised rib on the detector when the detector is in the fully home positionLoop cabling is connected to base terminals L -ve and L1 veA drive is provided for a remote indicator connected between loop positive and terminal RTerminal L2 is not used

GBP 14.99
1

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder DriverThe MTL5525 Isolating Sounder Driver enables an intrinsically safe sounder located in the hazardous area to be controlled from the safe area.The barrier is designed as a CE marked replacement for the existing MTL3021 barrier. It has one channel and is suitable for connecting loads in Zone 0 IIC T4-T6 hazardous areas if suitably certified. It enables an onoff device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area. It can drive loads such as solenoids alarms LEDs and other low power devices that are certified as intrinsically safe or are classified as nonenergy storing simple apparatus.MTL5500 Series isolating IS interface units offer a compact and easy-to-use means for communicating safely with process measuring indicating actuating and local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions amplifying or otherwise conditioning them as required and at the same time providing certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. The range has been designed for reliability. It builds on the proven success of the MTL2000 3000 4000 and 5000 Series to bring the benefits of new developments in galvanic isolation without compromising the reliability of the designs from which it has evolved. It is designed from the outset to meet all relevant European Directives. Uniform appearance and connectability of the units and a comprehensive range of accessories and enclosures make planning a pleasure for the user.Key FeaturesInput Type VoltageOutput Type VoltageSignal Conditioner Type IsolationInput Range 1.4 - 4.5 V dcOutput Range 7.8 - 24 VMounting Type DIN RailMinimum Operating Temperature -20CMaximum Operating Temperature 60CNumber of Channels 1Module Type SolenoidAlarm DriverTermination CableOperating Temperature Range -20 - 60 CSeries MTL5000

GBP 213.74
1