22 results (0,14602 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier 020-549 ID3000 Intelligent Dual Loop Board Kit E-LIB

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EB

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EB

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EBNFXI-ASD22-HS-EB addressable aspiration unit for connection to PEARL is addressed 1 - 159 interchangeable detectors has 2 pipe connections with 2 VIEW detectors.The FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a two channel loop which connects to the FAAST LT aspiration unit. It comes with 2 HSS detector and base and has a built-in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2756.46
1

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HS

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HS

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HSNFXI-ASD12-HS-EB addressable aspiration unit for connection to PEARL is addressed 1 - 159 interchangeable detectors has 1 pipe connection with 2 VIEW detectors.The FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a single channel loop which connects to the FAAST LT aspiration unit. It comes with 2 HSS detector and bases and also includes a built in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2794.58
1

Notifier M720E Analogue Addressable Dual Input Monitor Module

Notifier M720E Analogue Addressable Dual Input Monitor Module

Notifier M720E Analogue Addressable Dual Input Monitor ModuleThe M702E is designed for use with any Notifier protocol fire alarm control panel.Comes complete with end of line resistors plug-in screw connections direct decade address entry and tri-colour LEDs complete with Isolator..The newly designed platform of M700 family of InputOutput modules completes the NFXI line of wired spot detectors with unaltered family feeling and undisputed continuity.The new M700 look and feel combine maximum reliability with top-end functionality all enriched by a cutting-edge modern design.Single and multi-way models are available within the renewed mechanical package reducing both the cost of installation and the mounting space required.Their unique mechanical design allows each module to be mounted in either a common wall box on a DIN rail or its dedicated enclosure. The DIN rail mounting option is possible thanks to smart DIN brackets directly built-in the enclosure. Irrespective of the mounting methods chosen the address switch is always visible and accessible for selection.Each module has built-in short circuit protection for the communications loop however to increase application flexibility the isolators can be selecteddeselected on an individual module basis.To help technicians in the maintenance and fault-finding process light pipes have been enlarged to increase visibility even in the most challenging space constrained application. Both the status LED and the rotary switch selection can be viewed on the two sides without having to remove the cover of the surface mounting box.The multi-colour status LED provide diagnostic information regarding the status of each individual inputoutput. For ease of installation testing and maintenance modules have been equipped with quick connectors. The renovated aesthetics offers data finely engraved on the enclosures surface by laser for lifetime durability and resistance to degradation.

GBP 108.70
1

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay ModuleThe M721E is designed for use with any Notifier protocol fire alarm control panel.Comes complete with end of line resistors plug-in screw connections direct decade address entry and tri-colour LEDs complete with Isolator.The newly designed platform of M700 family of InputOutput modules completes the NFXI line of wired spot detectors with unaltered family feeling and undisputed continuity.The new M700 look and feel combine maximum reliability with top-end functionality all enriched by a cutting-edge modern design.Single and multi-way models are available within the renewed mechanical package reducing both the cost of installation and the mounting space required.Their unique mechanical design allows each module to be mounted in either a common wall box on a DIN rail or its dedicated enclosure. The DIN rail mounting option is possible thanks to smart DIN brackets directly built-in the enclosure. Irrespective of the mounting methods chosen the address switch is always visible and accessible for selection.Each module has built-in short circuit protection for the communications loop however to increase application flexibility the isolators can be selecteddeselected on an individual module basis.To help technicians in the maintenance and fault-finding process light pipes have been enlarged to increase visibility even in the most challenging space constrained application. Both the status LED and the rotary switch selection can be viewed on the two sides without having to remove the cover of the surface mounting box.The multi-colour status LED provide diagnostic information regarding the status of each individual inputoutput. For ease of installation testing and maintenance modules have been equipped with quick connectors. The renovated aesthetics offers data finely engraved on the enclosures surface by laser for lifetime durability and resistance to degradation.

GBP 150.07
1

Notifier NFXI-SMT3 Photo Thermal amp Infrared Multi-Criteria Detector - White

Notifier NFXI-SMT3 Photo Thermal amp Infrared Multi-Criteria Detector - White

Notifier NFXI-SMT3 Photo Thermal Infrared Multi-Criteria DetectorThe Opal multi-criteria multi-sensor photo thermal and infrared SMART3 detector is the environmentally friendly alternative to the ionisation detector a technology that is now over sixty years old. The SMART3 offers comparable speed of response to the ionisation technology for a fast flaming fire and is less susceptible to false alarms. It can be deployed with confidence in locations where the main risk is from fast-developing flaming fires. SMART3 moves the goal posts in the fight against false alarms by delivering enhanced false alarm immunity.In addition to being an effective alternative to ionisation units SMART3 offers better performance over the alternative technologies of dual angle or dual wavelength optical detectors and photo-thermal detectors. The integration of continual monitoring for all three major elements of a fire enables the SMART3 to respond far more quickly to an actual fire and has the highest immunity to nuisances. Based upon the sensor signals the program dynamically changes sensor thresholds sensor gain time delays combination sampling rates averaging rates and if any sensor fails changing sensitivity of the remaining sensors as well as indicating a fault condition.The sensing elements of the SMART3 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 89.23
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Includes1 x 020-538 - Basic Equipment kit 2-8 Loops1 x 020-579 - 7A PSU 4.5A or 7A User selectable1 x 020-543- Dual transmittion path board kit1 x 020-588 - Dual loop board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-485-009 - Extension cover blanking kit1 x 020-481-009 - Extension cover kit

GBP 4722.00
1

Notifier NFX-SMT3-IV Photo Thermal amp Infrared Multi-Criteria Detector - Ivory

Notifier NFX-SMT3-IV Photo Thermal amp Infrared Multi-Criteria Detector - Ivory

Notifier NFX-SMT3-IV Photo Thermal Infrared Multi-Criteria Detector - IvoryThe Opal multi-criteria multi-sensor photo thermal and infra-red SMART3 detector is the environmentally friendly alternative to the ionisation detector a technology that is now over sixty years old. The SMART3 offers comparable speed of response to the ionisation technology for a fast flaming fire and is less susceptible to false alarms. It can be deployed with confidence in locations where the main risk is from fast-developing flaming fires. SMART3 moves the goal posts in the fight against false alarms by delivering enhanced false alarm immunity.In addition to being an effective alternative to ionisation units SMART3 offers better performance over the alternative technologies of dual angle or dual wavelength optical detectors and photo-thermal detectors. The integration of continual monitoring for all three major elements of a fire enables the SMART3 to respond far more quickly to an actual fire and has the highest immunity to nuisances. Based upon the sensor signals the program dynamically changes sensor thresholds sensor gain time delays combination sampling rates averaging rates and if any sensor fails changing sensitivity of the remaining sensors as well as indicating a fault condition.The sensing elements of the SMART3 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key Features Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100 mechanical and electrical backwards compatibility Base designed to ease installation and wiring

GBP 157.37
1

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops3 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1x 020-548 - Optional status indicator board kit for 7A PSU1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H620mm W500mm D122mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer1 x 020-541-009 - 7A PSU78AH battery cabinet kit

GBP 6122.94
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops1 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable1 x 020-543 - Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 4599.50
1

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops2 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kitspace for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 5150.30
1

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EBThe FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a single channel loop which connects to the FAAST LT aspiration unit. It comes with 1 HSS detector and base and has a built in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2254.32
1

Notifier Honeywell Power Amplifier 4 x 125w 100v Class D 580242

Notifier Honeywell Power Amplifier 4 x 125w 100v Class D 580242

Notifier Honeywell Power Amplifier 4 x 125w 100v Class D 580242Four-channel power amplifier with built in battery charger for emergency power supply of VARIODYN D1 Comprio. 4XD125B has 4 independent amplifier channels each with 125 W in class D direct drive technology. Due to the fact that all amplifier channels are completely independent from each other it is possible to use one channel for back up.This could be for the other 3 channels or alternatively for other amplifier channels of other amplifiers with the same or lower output power only 4XDxxxB models. The amplifier may be used with the VARIODYN D1 Comprio as well as a DOM. It is also possible to use the amplifier with a separate PSU in this case the internal battery charger must be disabled.Key FeaturesEN 54-4 and EN 54-16 certifiedCompliant with EN 60849 and EN 50849Class D technology efficiency 80 4 independent amplifier channelsOne of four amplifier channels can be used as general back up channelOne height unitIdeal for use with the VARIODYN D1 ComprioSelf-monitoring and self-test by microcontrollerProtected against overload short circuit and overheatingSmooth and fast step-down in 1dB steps in the event of overdrive or over load24 V DC PSU for back up mains powerIntegrated battery charger according to EN 54-4 for charging batteries up to a capacity of 65 Ah 2 x 12 V 65 Ah for emergency power supply of the amplifier and one Comprio or DOMTemperature controlled variable speed fans

GBP 3463.82
1

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243Four-channel amplifier with integrated battery recharging system for the emergency power supply to the VARIODYN D1 Comprio. The 4XD250B features 4 independent amplifier channels each with 250 W in class D direct drive technology. Due to the fact that all amplifier channels are completely independent from each other it is possible to use one channel for back up.This could be for the other 3 channels or alternatively for other amplifier channels of other amplifiers with the same or lower output power only 4XDxxxB and 4XDxxxW models. The amplifier can be used in combination with the VARIODYN D1 Comprio as well as with a DOM. It is also possible to use the amplifier also with a separate PSU the internal PSU must be switched of then. In this case the internal battery charger must be disabled.Key FeaturesEN 54-4 and EN 54-16 certifiedCompliant with EN 60849 and EN 50849Class D technology efficiency 80 4 independent amplifier channelsOne of four amplifier channels can be used as general back up channelTwo Height Unit 2 HUIdeal for use with the VARIODYN D1 ComprioSelf-monitoring and self-test by microcontrollerProtected against overload short circuit and overheatingSmooth and fast step-down in 1dB steps in the event of overdrive or over load24 V DC PSU for back up mains powerIntegrated battery charger according to EN 54-4 for charging batteries up to a capacity of 65 Ah 2 x 12 V 105 Ah for emergency power supply of the amplifier and one Comprio or DOMTemperature controlled variable speed fans

GBP 5451.26
1

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKITThe NOTIFIER Local Silence Button in conjunction with the advanced programmingprovided by the Pearl control panel enables the use of a full BS5839 Part 1 system inapplications such as assisted living retirement homes student accommodation highrise residential buildings. Often the risk of false alarm in such buildings has led to thesesorts of installation being provided with individual systems for the flats linked to alandlord system for the shared area.The use of the NOTIFIER local silence button and Type-B dependency programmingnow enables full BS 5839 Part 1 systems to be installed in all areas.Type B DependencyType B dependency allows a zone to be defined for each individual flat that acts as ifit were a separate system. On receipt of an unconfirmed fire signal from a flat onlythe local alarm within the flat is given. If the alarm is confirmed by a second signal thesystem proceeds to the relevant evacuation stage general alarm or part of stagedevacuation. Alternatively if the confirmation signal is not given the system may resetautomatically without attendance by facility management staff.Local Silence ButtonThe local silence button is a multi-position switch that allows not only sounder test andsilencing but also disablement of smoke detection and the indication of disablement. Aswith other features it is flexible in configuration so that the facilities may be tailored tosuit each site.NOTIFIER NF-SIL-BKIT LOCAL SILENCE BUTTON KIT FEATURESBest detection throughout. AllowsOpal multi criteria detectors to reducefalse alarms.Fully configurable. Allowing theinstaller to design delay periods andresponse times on all parts of thesystem in order to ensure it meetsyour building requirements.Flexible and simple to install. TheLocal Silence Button is available in a kitincluding wiring loom and loop moduleSupporting compliance. BS5839 Part6 requires the alarm in each dwellingto be tested on a regular basis. Thisactivity is logged on the Pearl systemallowing landlords to check theresidents are performing this taskensuring fire safety and compliance.Local Silence of an AlarmThe user is able to silence the local sounder or sounder beacons within their premisesby pressing the Fire Alarm Silence button when a detector has activated within theirpremises. When the site is in a full evacuation mode this feature is disabled and thelocal sounder or sounder beacons cannot be silenced by the user.Local DisablementIf the user believes that they may generate an unwanted alarm from a smoke detectorwithin their premises they can press and hold the Fire Alarm Silence button for 5seconds. The yellow LED illuminates which will then disable the detection in that zoneonly for a configurable period of between 5-15 minutes in accordance with BS5839 Part 6.At the end of the configured period the zone will automatically re-enable all detectionwill be active and the LED will be extinguished.Local TestA test feature is available which allows the user to operate the sounder or sounderbeacons within the local zone by pressing and holding down the Fire Alarm Testbutton once released the sounder or sounder beacons will silence.ConnectionThe button is connected to the Pearl loop via a Notifier 21 dual input single outputinterface unit and a 5-core cable.

GBP 287.16
1