50 results (0,15988 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda VHX-1400 Metal Box HLI Modbus Type 1

Vesda Xtralis KA-1 Steam Trap

Vesda VHX-0400 PC Link Modbus MK1 HLI Type 1

Vesda Xtralis 25mm x 12 Condensation Valve Trap with Ball Valve

Vesda Xtralis M8 Nut - Pack of 10 PIP-029

Vesda Xtralis 25mm10mm Compression Adaptor Pack of 10

Vesda Xtralis WHTCTII0250-10 25mm10mm White Capillary Tee

Vesda Xtralis 128-015 Smoke Detector Pipe Label - Pack of 100

Vesda Xtralis 25mm In-line Expansion Socket 100mm PIP-019

Vesda VHX-1410 Metal Box HLI Modbus Type 2

Vesda Xtralis 128-014-XTR Label Sampling Point Roll of 100

Vesda Xtralis PIP-001-2.4 Red ABS Pipe - 2.4m Length Pack of 25

Vesda Xtralis 25mm to 38 BSP Female Air Line Adaptor PIP-022 Pack of 10

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish Honeywell OnlyThe VESDA ModBus High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs or Fire Alarm Control Panels FACPs otherwise known as host that support the ModBus protocol. There are two models availableModBus HLI Type 1 VHX-0400 which echoes each character received on the RS232 link back to the host together with reply message.ModBus HLI Type 2 VHX-0410 which has the echoing function disabled.Key FeaturesDirect access and monitoring of your VESDAnet system.Seamless data transfer.Easily configured using Xtralis configuring and monitoring software packages.DescriptionOne ModBus HLI is used to interface to a VESDAnet. Modbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet.The Modbus HLI supports VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides up the address range into to 7 logical networks. For example the first 30 addresses are considered in network 1 addresses between 31 to 60 are in network 2 and so on.Smoke and Alarm LevelsThe Smoke Level is reported relative to the Fire Alarm threshold where the full scale is 20. For example if the Fire Alarm threshold is 0.5 obsm a level of 0.1obsm is reported as 4. In other words the Actual Smoke level Reported smoke value Fire1 Threshold 20.FaultsAll VESDAnet faults are mapped on one or more of the Modbus HLI faults which are listed belowHead FaultHead Fault Battery and MainsHead Fault Scanner2 and Flow FaultVESDAnet faults categorised as network faults are mapped onto all zones whereas zone faults are mapped onto that particular zone.

GBP 1328.53
1

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 RelaysDisplay modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2-digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.There are various versions of the display module depending on the type of detector and the relay configuration required.Smoke IndicationSmoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level.To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.Status LightsHigh intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Numeric DisplayA 2 digit numerical readout has a number of modes that are indicated by up to four LEDs The current smoke level in obscurationm obscurationft Fire 1 threshold in obscurationm obscurationft. This is the sensitivity of the detectorKey Features Provides Immediate Status Reporting for a Single VESDA Zone Allows Zone Control of Assigned VESDA Detector High Intensity Alarm LEDs Remote Relay Option 20-Segment Vertical Bar Graph Display Alarm Threshold Indicators Built-In Sounder for Audible Warning Comprehensive Fault Reporting Multi-mode Numeric Display defaults to smoke obscuration Recessed Mounting Option

GBP 1014.77
1

Vesda Xtralis PIP-014 Pipe Cutters

Xtralis OSID-EHE OSID Emitter Environmental Housing

Xtralis OSID Imager Environmental Housing OSID-EHI

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relaysThe VRT-J00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1167.56
1

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 RelaysThe VRT-800 is a Remote Display Module designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1158.24
1