19 results (0,13737 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZCR868-C Conventional Wireless Communicator

Ziton ZCR868-C Conventional Wireless Communicator

Ziton ZCR868-C Conventional Wireless CommunicatorThe ZCR868-C is a 24VDC powered wireless cluster communicator for interfacing of wireless 868 MHz Ziton fire alarm devices into a conventional ZP fire alarm system. It enables these wireless devices to be controlled and monitored directly from the CIE and provides a seamless interface between wireless devices and the CIE.Wireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system.A cluster communicator comprises of a radio transceiver capable of communicating with up to 30 wireless devices. The ZCR868-C communicates directly to a ZCR452 connected to a conventional interface relaying all messages from the wireless field devices.Every wireless device controlled through a cluster communicator has its own unique address with which the cluster communicator communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units and remote indicators.When connected to a conventional interface the specific device message is translated into a general zone message for reporting to the CIE. Mode details including the address of the device and the specific alarm reported are however still available on the LCD display of the ZCR868-C greatly enhancing the diagnostic capabilities of the conventional wireless system.Key Features24VDC operation2-Way communication with up to 30 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-18 25 complaint and CPR certified

GBP 287.95
1

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit with Battery PackThe ZCR452 is an interface between a conventional fire detection zone and a range of wireless 868 MHz field devices. It provides a method of interfacing a conventional system with a zone of wireless field devices in areas where the installation of system wiring is not an option.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 allows for any compatible conventional fire detection zone to be connected directly to the unit. The ZCR452 in turn provides fire and fault notifications from the wireless field devices to these conventional circuits. In addition any conventional notification circuit may also be wired to the ZCR452 allowing wireless notification devices to be controlled from the conventional notification controller in a similar way to any hardwired conventional notification device.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. Any abnormal battery condition is reported to the fire system.Key FeaturesProvides conventional systems with wireless capabilitiesNo special conventional interfaces requiredFlexible impedance matching for conventional circuitsMonitors all wireless alarm and fault messagesConventional control interface for wireless notification devices and IOTwo way radio communicationFully EN54 compliant and CPR certified

GBP 194.32
1

Ziton ZR455V-3RR Wireless Red Sounder with Red Beacon

Ziton ZRW460-3WC Wireless Beacon with Battery Pack White Body White Flash

Ziton ZRW466-3WC Wireless Sounder VAD Wall Mount White Body White Flash

Ziton ZRW466-3C Wireless SounderVAD with Battery Pack Wall Mount White Flash

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar WhiteThe ZR432-2PA is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PA is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSounder with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 232.56
1

Ziton ZRC466-3C Wireless Sounder VAD Beacon with Battery Pack Ceiling Mount Red Body White Flash

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains PoweredThe ZPR868-CM is a mains powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key FeaturesMains supply with battery backup2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24VdcThe ZPR868-C is a 24VDC powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key Features24VDC supply2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZPR868 868 MHz - Multi-channel - Bi-directional Radio Loop Module

Ziton ZPR868 868 MHz - Multi-channel - Bi-directional Radio Loop Module

Ziton ZPR868 868 MHz - Multi-channel - Bi-directional Radio Loop ModuleThe ZPR868 is a Ziton protocol radio loop module for interfacing a zone of wireless 868 MHz Ziton fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP hardwired loop and provides a seamless interface between the hardwired components and the wireless devices.The ZPR868 comprises of a radio transceiver capable of receiving 31 radio devices. An LCD display is provided along with function buttons to allow programming and diagnostics to be carried out for associated devices. The interface is addressed on the loop via its onboard 8 way DIP switch. A total of 2 ZPR868 units may be fitted onto a single fire alarm control panel loop controlling up to 62 wireless loop devices.Every wireless device controlled through the ZPR868 has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Wireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. The ZPR868 allows the system designer full flexibility in selecting which devices on the loop are to be hardwired and which are to be wireless.Key FeaturesProgrammable to suit protected areaAutomatic selection from 32 radio channels for reliable signallingMultipath technology ensures a robust radio solutionDiversity transceivers allow maximum operational rangeComplies with EN300-220EN54-25 and CPD certified

GBP 378.32
1

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio SounderThe ZR455-3W is a WHITE addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tones

GBP 215.44
1

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery PackThe ZR455-3R is a RED addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tonesAcoustic self testDual battery supply5 year battery life at normal conditionsHarmonised European 868 MHz frequency bandCPD certified

GBP 215.44
1

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red IndicatorThe ZR432-2PAV is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder with visual indicator all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PAV is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders. The red 360 visual indicator non EN5423 complaint allows for a 0.5 Hz flash rate and supports the sounder activation for noisy environments.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSoundervisual indicator combination with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 318.46
1

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery PackThe ZR451-3 is a wireless 868 MHz single channel inputoutput unit. It provides a method of interfacing a supervised input or potential free output signal into and out of the fire detection and alarm system in areas where the installation of system wiring is not an option.The systemThe ZR451-3 communicates with the main control panel via a hardwired radio loop module that can be installed anywhere on the ZP loop. When the input gets an alarm signal it passes it via the radio loop module to the main fire control panel where it is processed. The output of the interface provides volt free change over contacts for connecting ancillary equipment and is programmed separately activated individually on in a group.High intensity LED indicators positioned on the ZR451-3 may be illuminated by a manually activated push button to identify when the interface has operated providing clear identification of the signal source.Installed as part of a ZP addressable system up to 127 line devices sensors call points or interface units may be connected to each of the control panel loops. Each wireless device is assigned its own IDENT address with which the main control panel communicates with it providing the same system facilities as directly wired devices.UsageAs an input the ZR451-3 may receive signals from other alarm equipment e.g. beam detectors aspiration detectors etc. Used as an output the unit switches equipment controlled by the fire detection system e.g. air conditioning systems magnetic door release units etc. Both input and output facilities are available from the same unit and may be operated simultaneously or individually as programmed at the fire control panel.Power supplyThe ZR451-3 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. The ZR451-3 features battery condition monitoring and reporting.Key FeaturesAddressable inputoutput interface unitWire free activationVolt free relay outputMonitored input for fire and faultTwo way radio communication

GBP 234.91
1