75 results (0,13752 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced Mxp-003 Standard Network Card MXPro 4

Advanced ExGo 8 Way Relay Output Card - EXP-008

Advanced MXP-503 Standard Network Card MxPro5

Advanced MXP-503 Standard Network Card MxPro5

Advanced MXP-503 Standard Network Card MxPro5The Ad-NeT network system allows all MxPro5 series control panels remote terminals and network peripherals to be connected together using standard fire resistant two-core cable. It provides both the benefits of distributed intelligence and reduced installation costs whilst catering for the smallest two-panel network through to the largest 200 panel wide area networked system.The network operates as a true peer-to peer system allowing information from any input or output device to be passed over the network and displayed on any MxPro5 control panel or remote terminal as required.Simply adding and connecting a network card allows any MxPro5 control panel or remote terminal to be networked. All other nodes on the Ad-NeT system will be instantly aware of a panel as soon as it is given a valid network node address allowing additional panels to be added at any time. All panels incorporate a network analyser providing valuable diagnostic and status information and also have the facility to prevent the transmission of fires or faults during commissioning.For more complex systems the Windows based PC-NeT Mx configuration software allows sector-based programming for Mute Silence Resound and Reset control keys as well as investigation delays group disablement and test instructions. All panels within the same sector will share common controls and each panel or remote terminal can also be programmed to show specific network information on a zonal basis. For cause and effect any input device can be programmed to operate any output device on any panel.Key FeaturesLarge Ad-NeT 200 Panel NetworkUp to 1.5Km between Control PanelsWindows based PC setupNetwork Systems share up to 1000 zonesNetwork Analysis from Control PanelStandard NetworkThe maximum total cable length is 1.5km. The maximum number of network nodes is 32 50 with signal bufferFault Tolerant NetworkThe maximum cable length is 1.5km between each node and the maximum total loop length is 20km. Each network card has in-built diagnostics and is fully monitored for both short and open circuit faults between nodes. The network is capable of withstanding a single fault between nodes without loss of communications to any single panel. The maximum number of network nodes is 200.

GBP 234.06
1

Advanced MxPro 5 MXP-537F 10-way Switch Input Card Fitted

Advanced MxPro MXP-034F Peripheral Bus - 4-Way Sounder Card Fitted

Advanced MxPro5 MXP-544F P-BUS 8-Way Relay Card Fitted

Advanced MxPro MXP-035F Peripheral Bus - 4-Way Relay Card Fitted

Advanced ExGo 8-Way Relay Output Card for use with EX-3001 only Fitted EXP-008F

Advanced MxPro5 MXP-544 P-BUS 8-Way Relay Card

Advanced MXP-034 Peripheral Bus - 4-Way Sounder Card