56 results (0,15194 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network.

GBP 114.65
1

C-Tec XFP761 XFP Network Card For 16 Zone Panels

C-Tec ECU722 SigTEL Network Communication Card

C-Tec QTS25 Quantec Surveyor2 IOT Card cw 12 Months Surveyor2 Access

C-Tec ECU723 SigTEL InterfaceNetwork Communication Card

C-Tec CFP Network Driver Card CFP761

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec CFP Relay Output Card Reset Fault Aux amp Remote Relay Outputs CFP762

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

C-Tec CFP763 Relay Output Card as per CFP762 8 outputs per zone relays

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteriesC-TECs tried and trusted XFP two loop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 13.With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful two loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Key features include 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 701.32
1

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah BatteriesC-TECs tried and trusted XFP oneloop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful one loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 557.02
1

C-Tec BF3593S Stainless Steel Glazed Enclosure