6 results (0,13922 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Carrier DF400 UltraLink Processor Module With 88 Relay OutputsInput - DIN-Rail Mount

Carrier ATS1204E 8-32 Zones DGP Input Expander 3A Power Supply Large Metal Housing EN Grade 3 Class II

Carrier ATS1201E 8-32 Zones DGP Input Expander 3A Power Supply Medium Metal Housing EN Grade 3 Class II

Carrier ATS1201E 8-32 Zones DGP Input Expander 3A Power Supply Medium Metal Housing EN Grade 3 Class II

Carrier ATS1201E 8-32 Zones DGP Input Expander 3A Power Supply Medium Metal Housing EN Grade 3 Class IIThe ATS1201ATS1203ATS1204 DGPs offer 8 standard inputs 8 Open Collectors OC outputs and a siren driver. The DGP can be expanded to a total of 32 inputs and 32 outputs. It has a built-in 3 A switched mode power supply.Data Gathering PanelsData Gathering Panels DGPs are used to expand the number of alarm inputs in an ATS MASTER ATS Classic system. DGPs allow inputs and outputs relays to be connected at a location remote from an ATS Classic panel. DGPs communicate via poll reply messages. Detectors door contacts and other detection devices are connected to DGPs that report any change of state to the control panel for processing. Available DGPs include support for conventional devices wireless devices as well as intelligent addressable devices. A special DGP available supports expansion of four intelligent doors or lifts.System databus connectionThe system databus is used to connect Data Gathering Panels as well as keypads and readers RASs to the ATS classic control panel. Remote devices can be up to 1.5 km from an ATS control panels when using the preferred wiring and cable types. Arming stations and Data Gathering Panels have to be connected via a 2 pair twisted and shielded data cable to the system databus connection to achieve this. WCAT 52 is recommended. Daisy chain is the preferred wiring method. The shield of the data cable should be connected to earth at the ATS control panel and should be left disconnected at any other end.

GBP 287.26
1

Carrier ATS1210LE 8 Zone Expander With InputOutput Connectors In Large Plastic Housing Grade 3

Carrier ATS1210LE 8 Zone Expander With InputOutput Connectors In Large Plastic Housing Grade 3

Carrier ATS1210LE 8 Zone Expander With InputOutput Connectors In Large Plastic Housing Grade 3The ATS1210LE expander offers 8 standard inputs and 8 Open Collector OC outputs expandable to 16 inputs or 16 outputs and is provided in the ATS1647 medium plastic housing. The expanders allow to increase the inputs and outputs of an Axon or an Advisor Advanced control panel or CDC4 series doorlift controller.ExpandersExpanders are used to expand the number of alarm inputs in an Axon panel or an Advisor Advanced system. Expanders allow inputs and outputsrelays to be connected at a location remote from an Axon or an Advisor Advanced panel. Expanders communicate via poll reply messages. Detectors door contacts and other detection devices are connected to expanders that report any change of state to the control panel for processing. Available expanders include support for conventional devices wireless devices as well as intelligent addressable devices. A special expander is available providing expansion of four to eight intelligent doors or lifts.System databus connectionThe system databus is used to connect expanders as well as keypads and readers RASs to Axon or the Advisor Advanced control panel.Remote devices can be up to 1.5 km from a control panels when using the preferred wiring and cable types. Keypads readers and expanders have to be connected via a 2 pair twisted and shielded data cable to the system databus connection to achieve this. WCAT52 is recommended. Daisy chain is the preferred wiring method. The shield of the data cable should be connected to earth at the control panel and should be left disconnected at any other end.FunctionalityExpanders provide information from remote locations to the control panels in structured records. Data collected ranges from a wired input state to wireless or addressable device dates to a door state.Bus devices communicate with the control panel. If a failure in communication occurs the expander remembers the last alarm in a system preventing loss of an alarm due to a short interruption in data communication.Up to 30 expanders can be connected to the system depending on the variant.Key Features8 inputs on boardExpandable to 16 inputs8 OC outputs on boardCompatible with Axon and Advisor Advanced panelsATS1647 plastic enclosure with tamper protectionEN50131 Grade 3PD66622010

GBP 121.75
1

Carrier CDC4-EN 4-8 Door Controller For Advisor Advanced - EN Approved

Carrier CDC4-EN 4-8 Door Controller For Advisor Advanced - EN Approved

Carrier CDC4-EN 4-8 Door Controller For Advisor Advanced - EN ApprovedThe CDC4-EN is a 4-8 door lift controller. It provides for a complete and versatile access control solution to extend the Advisor Advanced and Axon system with advanced access control functions. It provides a complete integrated real-time alarm and access control system for four up to eight doors or lifts with power supply and housing. A total of 12 doorlift controllers can be connected to an Advisor Advanced or Axon panel providing for a total of 48 up to 96 full access doors. The CDC4-EN doorlift controller can operate off-line with no degradation in performances should communication with the Advisor Advanced panel fail as it offers full offline operation. This combined intrusion and access solution reduces wiring and required devices as the same devices like readers and inputs can be used for both purposes. Being EN50131 and NFa2p approved the inputs and power supply for door contacts and detectors can be used as part of an approved intrusion system.Door and lift control can be used in one single door controller by configuring doors to lifts. The CDC4-EN provides for the same size and connector arrangement as the ATS1250 including 4 Wiegand interfaces. This provides the most cost effective and easiest method to upgrade an older ATS1250 in an Advisor Advanced system or when upgrading ATS Master with ATS1250s to a current system where the ATS Master is replaced by Advisor Advanced or Axon panel.Key FeaturesReal-time alarm access control on 4-8 doors lifts per controllerApproved for EN50131-3 and EN50131-6 NFa2p for use in intrusion systemsComplete database for offline operationUp to 12 CDC4-EN door controllers providing 48 to 96 intelligent doors or liftsCompatible with Axon and Advisor Advanced panelsAny door can be configured as lift use both together in one controllerFull access control features interlocking user count high secure users anti-passback with regionsUp to 65532 users with card andor PINUp to 32 readers per CDC4-EN and 6 per doorTwo local databuses with configurable protocolSupporting Secure readers OSDP readers and wireless locksOn board inputs 4 Wiegand interfaces door relays IP connection and expansion optionsExtended mode operation access control users managed by Advisor ManagementAnti-passback between all door controllers in standard mode connected to Advisor Advanced or Axon

GBP 1269.68
1