22 results (0,13911 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fike 505-0007 TwinflexPro2 Conventional Expansion Card

Fike 205-0003-NB Sita ASD Detector No Base

GBP 32.60
1

Fike Sita ASD Detector without Sounder 205-0003

Fike Sita ASD Detector without Sounder 205-0003

Fike Sita ASD Detector without Sounder 205-0003The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesMulti-mode detectionSelf-calibratingShort circuit isolatorAuxiliary input facility

GBP 33.78
1

Fike 205-0003-B Sita ASD Detector with Base - Black

Fike 205-0003-B Sita ASD Detector with Base - Black

Fike 205-0003-B Sita ASD Detector with Base - BlackThe Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesMulti-mode detectionSelf-calibratingShort circuit isolatorAuxiliary input facilityColour Black

GBP 48.77
1

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - BlackThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Colour- BlackModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 46.84
1

Fike 204-0003 Twinflex Multipoint ASD Detector

Fike 204-0003 Twinflex Multipoint ASD Detector

Fike 204-0003 Twinflex Multipoint ASD DetectorThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 32.12
1

Fike Sita ASD Detector with Sounder Strobe 205-0012

Fike Sita ASD Detector with Sounder Strobe 205-0012

Fike Sita ASD Detector with Sounder Strobe 205-0012The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesFast short circuit isolator in every device15 combinations of smoke heat detection modesMulti stage alarms - pre alarm feature7 sound patterns - plus off 3 different volume settings - if using Sita Multipoint with integral sounderAuxiliary digital inputs and outputs are available at any Addressable Multipoint deviceAutomatic continuous self calibrationAddressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicingMaintenance is made easy with the unique disposable optical chamber designed as a cost effective solution to cleaning and re-calibration

GBP 62.11
1

Fike 205-0012-NB Sita ASD Detector with Sounder and Strobe No Base

Fike 205-0012-NB Sita ASD Detector with Sounder and Strobe No Base

Fike 205-0012-NB Sita ASD Detector with Sounder and Strobe No BaseThe Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesFast short circuit isolator in every device15 combinations of smoke heat detection modesMulti stage alarms - pre alarm feature7 sound patterns - plus off 3 different volume settings - if using Sita Multipoint with integral sounderAuxiliary digital inputs and outputs are available at any Addressable Multipoint deviceAutomatic continuous self calibrationAddressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicingMaintenance is made easy with the unique disposable optical chamber designed as a cost effective solution to cleaning and re-calibrationNo base

GBP 63.18
1

Fike Sita ASD Detector with Sounder 205-0001

Fike Sita ASD Detector with Sounder 205-0001

Fike Sita ASD Detector with Sounder 205-0001The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesFast short circuit isolator in every device15 combinations of smoke heat detection modesMulti stage alarms - pre alarm feature7 sound patterns - plus off 3 different volume settings - if using SitaMultipoint with integral sounderAuxiliary digital inputs and outputs are available at any AddressableMultipoint deviceAutomatic continuous self-calibrationAddressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicingMaintenance is made easy with the unique disposable optical chamber designed as a cost effective solution to cleaning and re-calibration

GBP 51.58
1

Fike 205-0001-NB Sita ASD Detector with Sounder No Base

Fike 205-0001-NB Sita ASD Detector with Sounder No Base

Fike 205-0001-NB Sita ASD Detector with Sounder No BaseThe Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesFast short circuit isolator in every device15 combinations of smoke heat detection modesMulti stage alarms - pre alarm feature7 sound patterns - plus off 3 different volume settings - if using SitaMultipoint with integral sounderAuxiliary digital inputs and outputs are available at any AddressableMultipoint deviceAutomatic continuous self-calibrationAddressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicingMaintenance is made easy with the unique disposable optical chamber designed as a cost effective solution to cleaning and re-calibrationNo base

GBP 51.83
1

Fike 205-0001-B Sita ASD Detector with Sounder and Base - Black

Fike 205-0001-B Sita ASD Detector with Sounder and Base - Black

Fike 205-0001-B Sita ASD Detector with Sounder and Base - BlackThe Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesFast short circuit isolator in every device15 combinations of smoke heat detection modesMulti stage alarms - pre alarm feature7 sound patterns - plus off 3 different volume settings - if using SitaMultipoint with integral sounderAuxiliary digital inputs and outputs are available at any AddressableMultipoint deviceAutomatic continuous self-calibrationAddressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicingMaintenance is made easy with the unique disposable optical chamber designed as a cost effective solution to cleaning and re-calibration

GBP 66.77
1

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012The Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 60.25
1

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - Black

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - Black

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - BlackUsing the ASD Multipoint detector with sounder andor strobe as part of the TWINFLEXpro 2-wire fire alarm system means that when a detector is wired in so is an optional sounder with no extra wiring required. This greatly reduces the number of points that need to be installed and the time it takes to install In fact with the TWINFLEXpro exclusive 2-wire design installation savings can be as high as 40. Multipoint offers 7 different modes of detection which means one device can suit multiple applications. Whatever type of detection is required it can be selected with an easy flick of a switch at the time of commissioning.Sounders can be run on the same pair of wires as detectors andor call pointsNo extra devices needed for audible warningCan differentiate between call point smoke and heat alarmsTwo sound volumes easily selectable by dil switchUsing patented advanced optical scatter sensor design and sophisticated electronic technology Fike delivers reliable smoke andor heat detection significantly reducing the risk of nuisance fire alarms.Key Features7 modes of fire detection including combined smokeheatOptional built-in sounder andor strobe in a single deviceSelf-calibrates every 6 hoursContinuously monitors for dust contaminationEasily removable for maintenance at heightModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 54.48
1

Fike Twinflex Multipoint ASD Detector with Sounder - 204-0001

Fike Twinflex Multipoint ASD Detector with Sounder - 204-0001

Fike Twinflex Multipoint ASD Detector with Sounder - 204-0001Using the ASD Multipoint detector with sounder andor strobe as part of the TWINFLEXpro 2-wire fire alarm system means that when a detector is wired in so is an optional sounder with no extra wiring required. This greatly reduces the number of points that need to be installed and the time it takes to install In fact with the TWINFLEXpro exclusive 2-wire design installation savings can be as high as 40. Multipoint offers 7 different modes of detection which means one device can suit multiple applications. Whatever type of detection is required it can be selected with an easy flick of a switch at the time of commissioning.Sounders can be run on the same pair of wires as detectors andor call pointsNo extra devices needed for audible warningCan differentiate between call point smoke and heat alarmsTwo sound volumes easily selectable by dil switchUsing patented advanced optical scatter sensor design and sophisticated electronic technology Fike delivers reliable smoke andor heat detection significantly reducing the risk of nuisance fire alarms.Key Features7 modes of fire detection including combined smokeheatOptional built-in sounder andor strobe in a single deviceSelf-calibrates every 6 hoursContinuously monitors for dust contaminationEasily removable for maintenance at heightModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 39.94
1