8 results (0,14274 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fike NS100R-S Red Conventional Sounder - 12 to 56 VDC 95 - 110dB 32 Tones

Fike NS100R-D Red Conventional Sounder - 12 To 56 VDC - 95 To 110dB - 32 Tones - IP65

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Please note To access the software license for this product you mustcomplete official training with Fike. Please contact us directly before purchasing this product.Fike CIE-A-200 1 Loop Addressable Fire Alarm Control PanelThe CIE-A-200 Addressable Fire Alarm Control Panel is a one loop panel capable of supporting up to 200 devices with a maximum loop length of 2KM the panel also provides two configurable monitored input circuits 2 configurable monitored output circuits 2 configurable 1 fault relay and also a Peripheral bus circuit to add up to 8 repeater panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include alarm confirmation and delay timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-200 control panel is compatible with Fikes addressable range of devices and utilizes soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the Flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key Features1 loop addressable fire alarm panelCompatible with Fikes ASD addressable range of devicesFaster and easier installationImproved and easier to use OSP softwareSimple yet intuitive end user interfaceEnhanced service and fault-finding toolsUtilises soft addressing to eliminate physical address changes at each deviceFaster more reliable communication between panel and devicesSupports up to 200 Fike addressable devicesSupports a maximum loaded loop length of 2kmAccommodates 32 fire zones and 32 IO zonesFire and fault event log up to 1000 eventsProvides configurable monitored input and output circuits configurable relays and fault relayPeripheral bus circuit to add up to 8 repeater panelsLCD graphical user displayTechnical SpecificationDimensions Panel W x H x D 353mm x 333mm x 117mmMains Supply Input 230V AC NominalStandby Battery Requirement 2 x 7Ah 12V Sealed Lead Acid 2 x 12 Ah with extended battery boxMax Number of Loops 1Loop Loading 450 DLU 200 Devices MaxNumber of Supported Zones 32LCD Display LCD Graphical DisplayDevice Labels 31 Character

GBP 388.54
1

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater PanelThe CIE-A-400 Addressable Fire Alarm Control Panel is a two-loop panel capable of each loop supporting up to 200 devices with a maximum loop length of 2KM. The panel also provides two configurable Monitored Input Circuits 2 configurable Monitored Output Circuits 2 configurable Relays 1 Fault Relay and also a Peripheral Bus Circuit to add up to 8 Repeater Panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include Alarm Confirmation and Delay Timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-400 control panel is compatible with Fikes addressable range of devices and utilises soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key FeaturesSimply install and plug into Peripheral busRepeater control panel for the Fike CIE-A-400 2 loop addressable fire panelUp to 8 repeater panels can be connected on the same systemAllows control of the system from remote locations to the main fire panelRequires mains supply and 12v 12Ah back up batteriesSurface mount as standard flush mountable with additional cradle part number 23-0239

GBP 563.36
1

Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two Loops

Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two Loops

Please note To access the software license for this product youmustcomplete official training with Fike. Pleasecontact usdirectly before purchasing this product.Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two LoopsThe Fike CIE-A-400 Addressable Fire Alarm Control Panel is a powerful panel that supports up to 200 devices per loop covering a maximum loop length of 2KM. It offers two configurable Monitored Input Circuits two configurable Monitored Output Circuits two configurable Relays and one Fault Relay. With the Peripheral Bus Circuit you can connect up to 8 Repeater Panels for extended coverage.The system allows for flexible configuration with 3 alarm stages and comprehensive Zone to Zone Cause and Effect programming across all 32 panel zones. It includes Alarm Confirmation and Delay Timers along with 32 additional output zones for more complex programming needs.Compatible with Fikes addressable devices the CIE-A-400 utilises soft addressing principles eliminating the need for manual device addressing and preventing duplicate addressing issues. Operating parameters can be easily configured from the panel or OSP programming software and stored in device flash memory. This advanced digital protocol ensures faster and more reliable communication between detectors and the control panel.Key FeaturesCompatible with Fikes ASD addressable range of devicesFaster and easier installationImproved and easier to use OSP softwareSimple yet intuitive end user interfaceEnhanced service and fault finding toolsUtilises soft addressing to eliminate physical address changes at each deviceFaster more reliable communication between panel and devicesSupports up to 200 Fike addressable devices per loop including up to 100 sounders at 85 dB per loopSupports a maximum loaded loop length of 2kmFire and fault event logProvides configurable monitored input and output circuits configurable relays and fault relayPeripheral bus circuit to add repeater panelsLCD graphical user displayExpandable to two loops

GBP 757.70
1

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1