33 results (0,16280 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1

Fike TwinflexPro2 2 Zone Boxed Kit Approved - 604-0002

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1

Fike 313-0021 Twinflex Sounder Point Red

Fike 313-0022 Twinflex Sound Point White

Fike 302-0002 Twinflex Hatari Sounder White

Fike 302-0001 Twinflex Hatari Sounder Red

Fike 302-0012 Twinflex Low Profile Flash Point

Fike 540-0030 CIE-A-200 CIE-A-400 Fire Panel Flush Mount Bezel 540-0030

Fike 302-0022 Twinflex Domed Flash Point

Fike 520-0010 CIE-A-200 Repeater Panel

Fike 204-0003 Twinflex Multipoint ASD Detector

Fike 204-0003 Twinflex Multipoint ASD Detector

Fike 204-0003 Twinflex Multipoint ASD DetectorThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 32.12
1

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - BlackThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Colour- BlackModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 46.84
1

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012The Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 60.25
1

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater PanelThe CIE-A-400 Addressable Fire Alarm Control Panel is a two-loop panel capable of each loop supporting up to 200 devices with a maximum loop length of 2KM. The panel also provides two configurable Monitored Input Circuits 2 configurable Monitored Output Circuits 2 configurable Relays 1 Fault Relay and also a Peripheral Bus Circuit to add up to 8 Repeater Panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include Alarm Confirmation and Delay Timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-400 control panel is compatible with Fikes addressable range of devices and utilises soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key FeaturesSimply install and plug into Peripheral busRepeater control panel for the Fike CIE-A-400 2 loop addressable fire panelUp to 8 repeater panels can be connected on the same systemAllows control of the system from remote locations to the main fire panelRequires mains supply and 12v 12Ah back up batteriesSurface mount as standard flush mountable with additional cradle part number 23-0239

GBP 563.36
1

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Please note To access the software license for this product you mustcomplete official training with Fike. Please contact us directly before purchasing this product.Fike CIE-A-200 1 Loop Addressable Fire Alarm Control PanelThe CIE-A-200 Addressable Fire Alarm Control Panel is a one loop panel capable of supporting up to 200 devices with a maximum loop length of 2KM the panel also provides two configurable monitored input circuits 2 configurable monitored output circuits 2 configurable 1 fault relay and also a Peripheral bus circuit to add up to 8 repeater panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include alarm confirmation and delay timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-200 control panel is compatible with Fikes addressable range of devices and utilizes soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the Flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key Features1 loop addressable fire alarm panelCompatible with Fikes ASD addressable range of devicesFaster and easier installationImproved and easier to use OSP softwareSimple yet intuitive end user interfaceEnhanced service and fault-finding toolsUtilises soft addressing to eliminate physical address changes at each deviceFaster more reliable communication between panel and devicesSupports up to 200 Fike addressable devicesSupports a maximum loaded loop length of 2kmAccommodates 32 fire zones and 32 IO zonesFire and fault event log up to 1000 eventsProvides configurable monitored input and output circuits configurable relays and fault relayPeripheral bus circuit to add up to 8 repeater panelsLCD graphical user displayTechnical SpecificationDimensions Panel W x H x D 353mm x 333mm x 117mmMains Supply Input 230V AC NominalStandby Battery Requirement 2 x 7Ah 12V Sealed Lead Acid 2 x 12 Ah with extended battery boxMax Number of Loops 1Loop Loading 450 DLU 200 Devices MaxNumber of Supported Zones 32LCD Display LCD Graphical DisplayDevice Labels 31 Character

GBP 388.54
1

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - Black

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - Black

Fike 204-0001-B Twinflex Multipoint ASD Detector with Sounder - BlackUsing the ASD Multipoint detector with sounder andor strobe as part of the TWINFLEXpro 2-wire fire alarm system means that when a detector is wired in so is an optional sounder with no extra wiring required. This greatly reduces the number of points that need to be installed and the time it takes to install In fact with the TWINFLEXpro exclusive 2-wire design installation savings can be as high as 40. Multipoint offers 7 different modes of detection which means one device can suit multiple applications. Whatever type of detection is required it can be selected with an easy flick of a switch at the time of commissioning.Sounders can be run on the same pair of wires as detectors andor call pointsNo extra devices needed for audible warningCan differentiate between call point smoke and heat alarmsTwo sound volumes easily selectable by dil switchUsing patented advanced optical scatter sensor design and sophisticated electronic technology Fike delivers reliable smoke andor heat detection significantly reducing the risk of nuisance fire alarms.Key Features7 modes of fire detection including combined smokeheatOptional built-in sounder andor strobe in a single deviceSelf-calibrates every 6 hoursContinuously monitors for dust contaminationEasily removable for maintenance at heightModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 54.48
1