6 results (0,37682 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 540.001.039FC XB11 Flameproof Xenon Beacon

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 531.17
1

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 501.42
1

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 479.87
1

Fireclass 590.000.001FC NEO8060 Public Address and Voice Alarm System

Fireclass 590.000.001FC NEO8060 Public Address and Voice Alarm System

Fireclass 590.000.001FC NEO8060 Public Address and VoiceAlarm SystemLDA NEO 8060 is a compact EN 5416 certified PAVA systemthat ensures a ensures a fast safe and controlled emergency evacuation.NEO represents a costeffective voice evacuation and publicaddress system due to its cuttingedge features excellent audio quality andflexibility in just 2U 8 class D amplifiers 5 audio inputs 7x8 audio matrix39x1024 digital touch screen Cobranet audio etc.With the NEO Configurator software included it ispossible to configure the equipment remotely and create actions in the system triggered by conditions of input level datetime UDPcommand a GPIO or button from MPS microphone.Key FeaturesEN 5416 and EN60849 certified.Detection and indication of failure in all emergencyfunctions.Integration with fire alarm control panels.Prerecorded evacuation messages.Phased evacuation.Manual control of emergency states with access control.Recording output in emergency state.Emergency log.Loudspeaker line supervision.AB connection 16 lines.Back up amplifier connection 71 120 W channels or 41250 W channels.Rear viewFive audio inputs.Eight class D amplifiers with two configurations for 100V70V lines 8 class D amplifiers of 120 W per channel or 4 class D amplifiers of250 W per channel.Audio Matrix 7x8 digital up to 39x2014.Eight preamp outputs for external PA amplifiers connection.Up to eight multizone microphones MPS8Z or VAP1 panelsconnected with CAT5 UTP cable.DSP 7band inputoutput parametric equalizer loudness soundenhancer independent volume control per each I0 channel and audio filters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO Extensions indaisychain mode with Flexnet technology up to 1024 zones.43 frontal touch screen with access control.4 GB of internal memory for prerecorded messages.Integrated emergency microphone.Control for up to 32 attenuators AT6.Integrated frontal loudspeaker for monitoring.22 GPIO ports eight supervised for integrationwith fire alarm control panel.

GBP 5254.66
1

Fireclass DB3B Flameproof Horn Sounder - High Power

Fireclass DB3B Flameproof Horn Sounder - High Power

Fireclass DB3BDGD048N2BNRFC DB3B Flameproof Horn Sounder High Power Explosion Proof 122dB 1mThe DB3B is a high-power explosion proof sounder introduced as a replacement for the current DB3 with improved functionality and performance.Certified for use in a wide range of temperatures from -55C to 70C the Ex enclosure is manufactured from GRP with a rugged thermoplastic flare providing a corrosion free and aesthetically pleasing product.Capable of producing 122dB 1m and with a range of pre-recorded tones the DB3B includes an integral volume control which is ideal when a lower output is required.The unit is provided with versatile control options allowing compatibility with a wide range of control methods and PLCs.The standard DC unit provides 3 tone stages each stage has 28 tones available which can be independently selected. The unit can be controlled by reversing the polarity of the power supply 2 stage or providing a common negative and switching between multiple positive supplies. The DB3B proves its versatility by additionally being able to work with a common positive supply and switching the negatives. The tone stages of the DB3B can also be controlled via voltage free contacts provided by a control panel.Key FeaturesEx d Ex de IICIIIC T4T5T6ATEX certifiedIECEx certifiedUL certified for USA and Canada Class I Div 2 Groups A-D Class I Zone 1 Ex d IICAEx d IIC Gb Class II Div 2 Groups F G Zone 21 AEx tb IIIC Class III Div. 1TR CU certifiedCQST certifiedCCOE certifiedChinese Compulsory Certification for Fire systems CCCF certifiedINMETRO certifiedSIL 1 certifiedCSFM certifiedUp to 122dB output 1mIntegral volume control28 tones user selectable3 stage unit remotely switchableTones can be programmed to customers specificationDC supply voltage between 12V and 48VEx enclosure - glass reinforced polyesterFlare - high impact thermoplastic polyester

GBP 896.45
1