45 results (0,14655 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent 585050 Power Supply 1U - 24VDC 190A

Gent 585051 Power Supply 2U - 24VDC 380A

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 256.49
1

Gent SAFE-RED-D-KIT SAFE 2 Button Red Plus Interface

Gent SAFE-WHITE-D-SPARE SAFE 2 Button White Plus Loom

Gent SAFE-WHITE-D-KIT SAFE 2 Button White Plus Interface

Gent SAFE-RED-D-SPARE SAFE 2 Button Red Plus Loom

Gent SAFE-SS-D-KIT SAFE 2 Button Stainless Steel Plus Interface

Gent SAFE-SS-D-SPARE SAFE 2 Button Stainless Steel Plus Loom

Gent 19106-02 Timer Octal Base - 2-32 Secs DOE 24V DC cw Base

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful software processing in the panel quickly identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredPlease note This product requires 2 x 12v 12Ah Batteries NP12-12.

GBP 1579.67
1

Gent NANO-24 Nano Control Panel

GBP 540.34
1

Gent 13270-29 Flush Plate for 1-8 Panel and Repeat Panel Variants

Gent COMPACT-NC Compact Network Card

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 345.66
1

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 349.91
1

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 445.02
1