15 results (0,14062 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Global Fire Equipment OWL-6-OFFLINE OWL Graphical Software 6 Panels Offline

Global Fire Equipment OWL-1-OFFLINE OWL Graphical Software - 1 Panel Offline

Global Fire Equipment OWL-2-5-OFFLINE OWL Graphical Software - 2 -5 Panels Offline

Global Fire Equipment OWL-1-ONLINE OWL Graphical Software - 1 Panel Online

Global Fire Equipment OWL-2-5-ONLINE OWL Graphical Software - 2 -5 Panels Online

Global Fire CHAMELEON-REP Chameleon Control Repeater cw RS422 Network Card

Global Fire CHAMELEON-REPBLK Chameleon Control Repeater cw RS422 Network Card - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Sounder Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes.There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Sounder Beacon device can be connected to a single Loop depending on Loop Loading.All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper.There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Sounder Beacon A Shadow Sounder Beacon does not have an individual address thus freeing up addresses for more detection devices.Shadow Sounder Beacons do not report back to the control panel so their presence on the Loop is not monitored.Auxiliary Sounder Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED.When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command.This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event.Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Sounder Beacons is 63 and they can be allocated between address 1 and 63.

GBP 57.08
1

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with IsolatorThe addressable VULCAN 2 A is available as an Addressable SounderBeacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A SounderBeacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow SounderBeacon A Shadow SounderBeacon does not have an individual address thus freeing up addresses for more detection devices. Shadow SounderBeacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary SounderBeacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located.When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary SounderBeacons is 63 and they can be allocated between address 1 and 63.

GBP 50.70
1

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with Isolator

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with Isolator

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with IsolatorThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon devices can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 40.98
1

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 79.55
1

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 61.48
1

Global Fire Vulcan 2 ASI Addressable Red Base Sounder with Isolator

Global Fire Vulcan 2 ASI Addressable Red Base Sounder with Isolator

Global Fire Vulcan 2 ASI Addressable Red Base Sounder with IsolatorThe addressable VULCAN 2 A is available as an Addressable Sounder base which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Sounder device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Sounder A Shadow Sounder does not have an individual address thus freeing up addresses for more detection devices. Shadow Sounders do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Sounder When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED.When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Sounders is 63 and they can be allocated between address 1 and 63.Please Note this unit doesnt come with the lid as illustrated in the picture above please buy separately.

GBP 35.05
1

Global Fire G-ONE 1 Loop Control Panel - Non Expandable

Global Fire G-ONE 1 Loop Control Panel - Non Expandable

Global Fire G-ONE 1 Loop Control Panel - Non ExpandableThe G-One is a versatile compact addressable Fire Alarm Control Panel which can be surface or recess mounted.The powerful cause and effect programming capabilities along with enhanced system diagnostics performance makes this control panel suitable for a wide range of applications from small to large buildings or sites with complex multiple areas.With the addition of a network card the G-One incorporates the advanced peer-to-peer multi-master Chameleon Networking communications protocol.The Chameleon Network can accommodate up to 32 networked fire alarm control panels NODEs.Each control panel NODE has its own internal configuration along with the entire Network configuration backed up which provides a high level of networking security and resilience required for distributed fire detection and alarm systems.The G-One fire alarm control panel uses either RS 422 or Fibre Optic communications for the network which is usually wired in a fault-tolerant loop configuration providing multi-path system integrity for high speed monitoring and data communication. Additional ethernet interfaces provide further networking options allowing the system to communicate over other infrastructures.The control panel also has the provision to connect to CHAMELEON repeater panels using any of the networking interfaces of the CHAMELEON Networking protocol.The high resolution high contrast backlit blue graphical LCD display provides a clear and effective user interface which can accommodate any type of custom characters or graphical symbols allowing multiple language support as well as pictorial and customisable elements.The G-One can be securely accessed remotely via our proprietary ODYSSEY Graphics Interface or our TCPIP-WEB monitoring platform.Integration with third-party Building Management Systems BMS is provided via a dedicated Modbus output.The system programming can easily be done on-site via the onboard navigation keypad or by using the powerful PC CHAMELEON CONNECTOR configuration software which is downloaded to the control panel or broadcast to the network via a USB connection.Key Features900mA single loop digital communication addressable fire alarm control panelUp to 32 G-One GEKKO OCTO and NODE panels can be networkedConnection to the repeater panels via RS422 Fibre-Optic or TCPIP250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra-low current base sounders 32 address limit per loop.32 individually programmable sounder addressesFull Self-Addressing device support2 Fire output relays change-over and 1 Fault relay NC2 Non-addressable conventional alarm outputs individually programmableHigh integrity loop communication and device monitoring384 fully programmable network zones512 fully programmable alarm sounder groups512 IO groupsEvent log 10000 eventsCompatible with ZEOS GFE and Apollo digital analogue addressable protocolsCompatible with all GFE manufactured digital addressable ancillary modulesHigh resolution high contrast backlit blue graphical LCD display 240 x 64 pixelsProgramming by integrated tactile keypad or USB Loader PC softwareMultiple menu selectable language support16 integrated programmable fire zone LEDsSMS and EMAIL notification by means of TCP IP-WEB interfaceInstaller friendly automatic self-learn facilityCPR Certified to EN54-2 and EN54-4

GBP 413.40
1

Global Fire G-1BLK G-ONE 1 Loop Control Panel - Non Expandable - Black

Global Fire G-1BLK G-ONE 1 Loop Control Panel - Non Expandable - Black

Global Fire G-1BLK G-ONE 1 Loop Control Panel - Non Expandable - BlackThe G-One is a versatile compact addressable Fire Alarm Control Panel which can be surface or recess mounted.The powerful cause and effect programming capabilities along with enhanced system diagnostics performance makes this control panel suitable for a wide range of applications from small to large buildings or sites with complex multiple areas.With the addition of a network card the G-One incorporates the advanced peer-to-peer multi-master Chameleon Networking communications protocol.The Chameleon Network can accommodate up to 32 networked fire alarm control panels NODEs.Each control panel NODE has its own internal configuration along with the entire Network configuration backed up which provides a high level of networking security and resilience required for distributed fire detection and alarm systems.The G-One fire alarm control panel uses either RS 422 or Fibre Optic communications for the network which is usually wired in a fault-tolerant loop configuration providing multi-path system integrity for high speed monitoring and data communication. Additional ethernet interfaces provide further networking options allowing the system to communicate over other infrastructures.The control panel also has the provision to connect to CHAMELEON repeater panels using any of the networking interfaces of the CHAMELEON Networking protocol.The high resolution high contrast backlit blue graphical LCD display provides a clear and effective user interface which can accommodate any type of custom characters or graphical symbols allowing multiple language support as well as pictorial and customisable elements.The G-One can be securely accessed remotely via our proprietary ODYSSEY Graphics Interface or our TCPIP-WEB monitoring platform.Integration with third-party Building Management Systems BMS is provided via a dedicated Modbus output.The system programming can easily be done on-site via the onboard navigation keypad or by using the powerful PC CHAMELEON CONNECTOR configuration software which is downloaded to the control panel or broadcast to the network via a USB connection.Key Features900mA single loop digital communication addressable fire alarm control panelUp to 32 G-One GEKKO OCTO and NODE panels can be networkedConnection to the repeater panels via RS422 Fibre-Optic or TCPIP250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra-low current base sounders 32 address limit per loop.32 individually programmable sounder addressesFull Self-Addressing device support2 Fire output relays change-over and 1 Fault relay NC2 Non-addressable conventional alarm outputs individually programmableHigh integrity loop communication and device monitoring384 fully programmable network zones512 fully programmable alarm sounder groups512 IO groupsEvent log 10000 eventsCompatible with ZEOS GFE and Apollo digital analogue addressable protocolsCompatible with all GFE manufactured digital addressable ancillary modulesHigh resolution high contrast backlit blue graphical LCD display 240 x 64 pixelsProgramming by integrated tactile keypad or USB Loader PC softwareMultiple menu selectable language support16 integrated programmable fire zone LEDsSMS and EMAIL notification by means of TCP IP-WEB interfaceInstaller friendly automatic self-learn facilityCPR Certified to EN54-2 and EN54-4Colour Black

GBP 413.40
1