Hyfire HFI-IM-SM-01 Mini Mount Single Supervised Input Module

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised OutputThe module is a single input and single supervised output mini module. The module contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFI-IO-SM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to remotely monitor a single circuit and control a single ancillary circuit using external power. Both input and output circuits are monitored for fault conditions. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeProvides both a fully monitored input and output circuitFast fit plug-in cable connectionsAlternate mechanical variants available to satisfy different applicationsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay OutputSingle input and single relay output mini module. VMMIC120 contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFIIO- RM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to both remotely monitor a single circuit and control a single ancillary circuit using a set of volt-free changeover relay contacts. The input circuit is monitored for fault condition. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeCan both monitor an input circuit and switch dual volt-free changeover relay contactsFast fit plug-in cable connectionsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HF-CP4-1-52 1-4 Loop Panel cw 1 Loop Card

GBP 2012.21
1

Hyfire HF-CP2-1-52 1-2 Loop Panel cw 1 Loop Card

GBP 1429.54
1

Hyfire HFI-OM-RM-01 Mini Mount Single Relay Output Module

Hyfire HFI-OM-SM-01 Mini Mount Single Supervised Output Module

Hyfire HY50 Go 1 Loop Panel 50 Devices

Hyfire HY50 Go 1 Loop Panel 50 Devices

Hyfire HY50 Go 1 Loop Panel 50 DevicesThe HyFire HY50 allows connection of up to 50 HyFire wireless devices and features a new ergonomic layout of control panel combined with a high resolution high contrast graphical LCD display.The tactile keypad allows simple select-and-click programming for faster engineer configuration and simple end-user operation.Functional improvements include integral zonal LEDs which enable instant identification of alarm locations and ensure compliance with BS5839 without the cost of a separate LED zone card. Powerful cause-and-effect programming and enhanced trace diagnostics make the panel suitable for a wide range of site applications from small to medium systems. All Go series panels are fully programmable on site via the control panel display or with Hyfires updated easy-to-use PC Configuration Tool.Key FeaturesHyFire wireless protocol enabledGraphical LCD user interface LED indicators push buttonsInstaller-friendly Auto-learn Loop detection and On-board scope facility500 fire 5000 general event logging with advanced diagnostic precision to aid installation fault-findingIntegral 15 Zone LEDs ensures compliance with BS5839 with 35 additional software indication zonesUses a new Configuration Tool with Office365 appearance with better graphics and easier functions for programmingTwo on-board Sounder outputs three on-board Relay outputsOptional 3 monitored inputoutputs for FireFault routing with P-Bus adaptor routing card for full EN54 compliance when connected to an Alarm Receiving CentreDedicated USB Type B port for direct PC connectionEthernet port for Cloud connection via Advanced Live to provide remote notification and panel managementInnovative no hinge removable door and hangable chassis for easier installationEmploying an identical monitoring feature as the Mx-5000 series the Go series meets the requirements of EN54-13 2005 Clauses 5.3.4.1 and 5.3.4.2 partial open short circuits for optimal fire system performance and complete peace of mind

GBP 766.58
1

Hyfire HY240 Go 1 Loop Panel 240 Devices

Hyfire HY240 Go 1 Loop Panel 240 Devices

Hyfire HY240 Go 1 Loop Panel 240 DevicesThe HyFire HY240 allows connection of up to 240 HyFire wireless devices and features a new ergonomic layout of control panel combined with a high resolution high contrast graphical LCD display.The tactile keypad allows simple select-and-click programming for faster engineer configuration and simple end-user operation.Functional improvements include integral zonal LEDs which enable instant identification of alarm locations and ensure compliance with BS5839 without the cost of a separate LED zone card. Powerful cause-and-effect programming and enhanced trace diagnostics make the panel suitable for a wide range of site applications from small to medium systems. All Go series panels are fully programmable on site via the control panel display or with Hyfires updated easy-to-use PC Configuration Tool.Key FeaturesHyFire wireless protocol enabledGraphical LCD user interface LED indicators push buttonsInstaller-friendly Auto-learn Loop detection and On-board scope facility500 fire 5000 general event logging with advanced diagnostic precision to aid installation fault-findingIntegral 15 Zone LEDs ensures compliance with BS5839 with 35 additional software indication zonesUses a new Configuration Tool with Office365 appearance with better graphics and easier functions for programmingTwo on-board Sounder outputs three on-board Relay outputsOptional 3 monitored inputoutputs for FireFault routing with P-Bus adaptor routing card for full EN54 compliance when connected to an Alarm Receiving CentreDedicated USB Type B port for direct PC connectionEthernet port for Cloud connection via Advanced Live to provide remote notification and panel managementInnovative no hinge removable door and hangable chassis for easier installationEmploying an identical monitoring feature as the Mx-5000 series the Go series meets the requirements of EN54-13 2005 Clauses 5.3.4.1 and 5.3.4.2 partial open short circuits for optimal fire system performance and complete peace of mind

GBP 934.27
1

Hyfire HF-CP4-3-52 1-4 Loop Panel cw 3 Loop Cards

Hyfire HF-CP4-3-52 1-4 Loop Panel cw 3 Loop Cards

Hyfire HF-CP4-3-52 1-4 Loop Panel cw 3 Loop CardsSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 2416.21
1

Hyfire HF-CP4-2-52 1-4 Loop Panel cw 2 Loop Cards

Hyfire HF-CP4-2-52 1-4 Loop Panel cw 2 Loop Cards

Hyfire HF-CP4-2-52 1-4 Loop Panel cw 2 Loop CardsSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 2214.22
1

Hyfire HF-CP1-52 Single Loop Panel

Hyfire HF-CP4-4-52 1-4 Loop Panel cw 4 Loop Cards

Hyfire HF-CP4-4-52 1-4 Loop Panel cw 4 Loop Cards

Hyfire HF-CP4-4-52 1-4 Loop Panel cw 4 Loop CardsSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 2618.21
1

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop Cards

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop Cards

Hyfire HF-CP2-2-52 1-2 Loop Panel cw 2 Loop CardsSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 1631.53
1

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep Enclosure

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep Enclosure

Hyfire HF-CP1-LD-52 Single Loop Panel - Deep EnclosureSpecifically programmed for use with the HyFire range of wired and wireless detectors the HF-CP1-52 control panel is supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Key FeaturesHyFire wired and wireless compatible20 programmable zonal 25 System LEDsAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and Onboard Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesProgrammable push buttonsRack-mount optionsMultiple languagesGlobal complianceFully networkable3-year warrantyFully programmable

GBP 1467.20
1