16 results (0,14178 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec K1620203 Battery Box to Match Syncro Styling Max 17 AH Battery Surface

Kentec K1619911 Battery Box to Match Syncro Styling Max 24 AH Battery Surface

Kentec K1630313 Battery Box to Match Syncro Styling Max 38 AH Battery Surface

Kentec K1610245 Battery Box to Match Syncro Styling Max 65 AH Battery Surface

Kentec K16100D3 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 38 AH Battery Surface

Kentec K25250M2 Sigma Power Supply Unit - 2.5A Max 7Ah Battery

Kentec K25250M2 Sigma Power Supply Unit - 2.5A Max 7Ah Battery

KentecK25250M2Sigma Power Supply Unit - 2.5A Max 7Ah BatterySyncro Power EN54-4 compliant power supplies provide a stable and fully regulated true 24V output for fire alarm system applications under all power conditions. The unique regulation techniques ensure that even when running on standby batteries a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected are supplied with optimum power.The powerful onboard micocontroller ensures that all battery types are conditioned with optimum temperature compensated charging algorythms to maximise battery life and maintain batteries in top condition. Syncro Power EN54-4 compliant power supplies can be fitted with an optional dual fused output monitoring module to ensure compliance with European standards when supplying fire control panels with an external power supply.Enclosed units are available to match both Sigma and Syncro equipment ranges and all are finished with matching livery and provide power on and power fault indications.Key Features2.5A and 5.25A versionsChassis only or enclosure mounted with battery space110V or 230V inputRegulated true 24V outputIntelligent battery charging and temperature compensationHouse up to 26Ah batteriesStatus indicators for monitored faultsDual output option for powering fire alarm control panels remotelyChassis versions have same mounting pointsFully enclosed and robust construction

GBP 382.81
1

Kentec K2525003 Power Supply Boxed 2.5 Amp PSU Max 12 AH Battery Surface

Kentec K2525003 Power Supply Boxed 2.5 Amp PSU Max 12 AH Battery Surface

Kentec K2525003 Power Supply Boxed To match Syncro Styling 2.5 Amp PSU Max 12 AH Battery SurfaceSyncro Power fully certified to EN54-4 power supplies provide a stable and fully regulated true 24V output for fire alarm system applications under all power conditions.The unique regulation techniques ensure that even when running on standby batteries a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected are supplied with optimum power.The powerful onboard microcontroller ensures that all battery types are conditioned with optimum temperature compensated charging algorithms to maximise battery life and maintain batteries in top condition.Syncro Power EN54-4 compliant power supplies can be fitted with an optional dual fused output monitoring module to ensure compliance with European standards when supplying fire control panels with an external power supply.Enclosed units are available to match both Sigma and Syncro equipment ranges and all are finished with matching livery and provide power on and power fault indications. Optional dual output path KD variant available to provide two independent supply paths between the power supply unit and the control panel in accordance with EN54-4 clause 6.4 and BS5839 pt1 clause 12.2.2.m requirements.Key Features2.5A and 5.25A versionsChassis only or enclosure mounted with battery space110V or 230V inputRegulated true 24V outputIntelligent battery charging and temperature compensationHouse up to 26Ah batteriesStatus indicators for monitored faultsDual output option for powering fire alarm control panels remotelyChassis versions have same mounting points

GBP 437.34
1

Kentec Switched Mode Power Supply Charger - 5.25 Amp PSU K406

Kentec K407 Switched Mode Power Supply Charger - 2.5 Amp PSU

Kentec KD25250M2 Dual Power Output Supply Boxed

Kentec KD25250M2 Dual Power Output Supply Boxed

Kentec KD25250M2 Dual Power Output Supply Boxed To match Sigma CPXT Styling 2.5 AmpPSU Max 7 AH Battery SurfaceSyncro Power fully certified to EN54-4 power supplies provide a stable and fully regulated true 24V output for fire alarm system applications under all power conditions.The unique regulation techniques ensure that even when running on standby batteries a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected are supplied with optimum power. The powerful onboard microcontroller ensures that all battery types are conditioned with optimum temperature compensated charging algorithms to maximise battery life and maintain batteries in top condition.Syncro Power EN54-4 compliant power supplies can be fitted with an optional dual fused output monitoring module to ensure compliance with European standards when supplying fire control panels with an external power supply. Enclosed units are available to match both Sigma and Syncro equipment ranges and all are finished with matching livery and provide power on and power fault indications.Optional dual output path KD variant available to provide two independent supply paths between the power supply unit and the control panel in accordance with EKey Features2.5A and 5.25A versionsChassis only or enclosure mounted with battery space110V or 230V inputRegulated true 24V outputIntelligent battery charging and temperature compensationHouse up to 26Ah batteriesStatus indicators for monitored faultsDual output option for powering fire alarm control panels remotelyChassis versions have same mounting points

GBP 429.61
1

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2

Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration

GBP 361.14
1

Kentec Sigma CP 4 Zone Conventional Fire Alarm Panel K11040M2

Kentec Sigma CP 4 Zone Conventional Fire Alarm Panel K11040M2

Kentec Sigma CP 4 Zone Conventional Fire Alarm PanelK11040M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration

GBP 318.37
1

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP2 Zone Conventional Fire Alarm PanelThe Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11 range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configurationSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power output

GBP 300.32
1