11 results (0,14351 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley CWSO-RR-S1 Red Low Profile Wall Ceiling Sounder

Morley CWSO-WW-S1 White Low Profile Wall Ceiling Mounted Sounder

Morley EVCS-XC 8-Way Exchange Unit

Morley MI-BRH-PC-I Red Flash Pure White Body Clear Lens Intelligent Detector Base High Performance Sounder Strobe cw Isolator

Morley MI-BRS-PC-I Red Flash Pure White Body Clear Lens Intelligent Detector Base Standard cw Isolator

Morley CWSS-RR-S5 Sounder VAD Beacon Red Body with Red Flash

Morley BRH-PC-I00 High Performance Detector Base Sounder Strobe - EN54-23 C

Morley BRH-PC-I00 High Performance Detector Base Sounder Strobe - EN54-23 C

Morley BRH-PC-I00 High Performance Detector Base Sounder Strobe - EN54-23 CMorley-IASs Detector Base Sounder Strobe is a modular high-output loop powered device intended to alert all building occupants of a potential fire.Approved to EN54-23 EN54-17 it enables a complete fully compliant and cost-effective fire alarm system by reducing installation and commissioning costs through fewer wiring points.The Honeywell Morley-IAS solution enables easy system extensions in legacy and new projects thereby providing the highest level of protection for all building occupants from a trusted brand.Key FeaturesRed FlashPure White BodyClear LensHigh PerformanceComes with IsolatorPremium and standard offering provides flexible solution to suit all space requirementsGlobal approved 32 tone set selectable from device or from panelAutomatic synchronization of sounder and strobeMaximum light and sound output with efficient power consumption enables more devices on a loopPremium device with high light coverage reduces wiring pointsSingle point of installation - saves time cost inventoryRed flash - industry preferred colour for evacuationEnvironmental RoHS WEEE REACHLarge cable access rear or surface cable entryAdjustable sound light tones to suit varying installation applicationsSimple twist fit onto universal B501AP baseRotary wheels address tags for clear address indicationLoop continuity spring supports first fix installationMeets detector spacing thereby reducing requirement for additional strobe devicesFewer wiring points for cost effective installation and simplified system maintenanceModular design allows individual components to be replaced separatelyBackwards compatibility with red flash B501 base

GBP 86.06
1

Morley BRS-PC-I00 Intelligent Detector Base Sounder Strobe - EN54-23 C

Morley BRS-PC-I00 Intelligent Detector Base Sounder Strobe - EN54-23 C

Morley BRS-PC-I00 Intelligent Detector Base Sounder Strobe - EN54-23 CMorley-IASs Detector Base Sounder Strobe is a modular high-output loop powered device intended to alert all building occupants of a potential fire.Approved to EN54-23 EN54-17 it enables a complete fully compliant and cost-effective fire alarm system by reducing installation and commissioning costs through fewer wiring points.The Honeywell Morley-IAS solution enables easy system extensions in legacy and new projects thereby providing the highest level of protection for all building occupants from a trusted brand.Key FeaturesRed FlashPure White BodyClear LensComes with IsolatorPremium and standard offering provides flexible solution to suit all space requirementsGlobal approved 32 tone set selectable from device or from panelAutomatic synchronization of sounder and strobeMaximum light and sound output with efficient power consumption enables more devices on a loopPremium device with high light coverage reduces wiring pointsSingle point of installation - saves time cost inventoryRed flash - industry preferred colour for evacuationEnvironmental RoHS WEEE REACHLarge cable access rear or surface cable entryAdjustable sound light tones to suit varying installation applicationsSimple twist fit onto universal B501AP baseRotary wheels address tags for clear address indicationLoop continuity spring supports first fix installationMeets detector spacing thereby reducing requirement for additional strobe devicesFewer wiring points for cost effective installation and simplified system maintenanceModular design allows individual components to be replaced separatelyBackwards compatibility with red flash B501 base

GBP 77.11
1

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01Morley-IAS Max fourloop expandable to eight networkable For System Sensor Apollo protocolMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 1772.89
1

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor amp Apollo

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor amp Apollo

Morley MA-1000-01 Morley-IAS Max Single Loop Non-Networkable For System Sensor ApolloMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 826.88
1

Morley MA-2000-01 Morley-IAS Max 2 Loop

Morley MA-2000-01 Morley-IAS Max 2 Loop

Morley MA-2000-01 Morley-IAS Max 2 LoopMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 1102.98
1