28 results (0,14023 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley 795-048 ZXe Loop Driver Card for Apollo Series 90 or XP95 Protocol

Morley ZX 4-Way Programmable Sounder Card

Morley MA-LCD7 Max 7quot Touchscreen RepeaterZonal Mimic

Morley ZX 4-Way Programmable Output Relay Module

Morley Network 16 Digital Master Panel EVCS-MPX-16

Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Multi-Protocol

Morley DXc2 Addressable 2 Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley DXc2 2 Loop Addressable Control Panel Multi-Protocol

Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Multi-Protocol

Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Morley-IAS Protocol

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TS

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TS

Morley Intelligent Hand-Held Diagnostic Test Unit for Analogue Loops POL-200-TSThe POL-200-TS loop tester is a versatile measurement and analysis tool that assists technicians with the installation and maintenance of fi re detection systems. The POL-200-TS recognizes all addressable loop elements with the CLIP OPAL ADVANCED Notifier Morley-IAS System Sensor and Honeywell protocols. In addition the loop tester is portable and easy to use so you can work loop by loop before the panel is installed from any location on the loop.Innovative InterfaceUsing the device is simple graphical touch screen with user-friendly icons and clear automated one-touch functions. It can even be used while wearing gloves.Loop MappingThe mapping function uses the device isolators to check the loop cabling topology and map the loop. On the screen it is possible to see the production date and detailed information of detectors inputs and outputs. Similarly one can read the status of equipment or even detect internal equipment faults.Maintenance and TestingThe log function generates a data fi le including information regarding the status of each loop device. It allows accurate control of system operation through the loop and device status report to anticipate and record equipment maintenance tasks.Simple OperationThe touch screen is designed for maximum simplicity with intuitive icons. The device performs the functions automatically when these are selected. The loop display clearly identifies the equipment type position and number of loop components.Key FeaturesVerification and maintenanceColour touch-screenUser-friendly functionalityCompatibility with CLIP OPAL ADVANCED Notifier Morley-IAS System Sensor and Honeywell protocolsTesting of loop faults short circuits from positive and or negative to shieldingDetailed information and device controlStatus logInternal memory and USB port for PC connection update or download recordings12VDC power supply or internal batteries

GBP 2138.72
1

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01 Morley-IAS Max four Loop expandable to eight networkable For System Sensor amp Apollo protocol

Morley MA-8000-01Morley-IAS Max fourloop expandable to eight networkable For System Sensor Apollo protocolMorley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.The system offers fire detection solutions integrated for many applications like hotels offices hospitals industrial environments and production facilities.Morley MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol originally designed for operation in industrial environments makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.The system is certified in compliance with the standards EN54-2 EN 54-4 and EN54-13.FEATURES AND BENEFITS USER INTERFACEThe ergonomic user interface is designed so that every operation is easy and intuitive. The panel has a 7 TFT touch display 800 x 480 with backlight with 256 colours for entering the control panel programming data and interacting with the operators.NETWORK BETWEEN PANELSEach control panel can be networked thanks to its two high-speed opto-isolated CAN bus lines for connecting a fail-safe closed loop network. With components distributed throughout the building up to 64 panels or 128 loops can be networked together to build a unified system that shares events and logic. All networked panels include built-in CAN bus network diagnostics with visual topology for fast and simple fault finding.MULTIPLE INSTALLATION OPTIONSMorley MAx panels offer multiple installation options in addition to standard wall mounting special frames are available for flush mounting options to deliver high-quality design in commercial or luxury environments. Furthermore MA-2000 and MA-8000 can be installed in a standard 19 rack without additional kits.Key Features4 access levels in accordance with EN 54 standards.Programmable text 32 characters for points and zones.Up to 2000 soft zones 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.Control-by-event CBE equations for activations with logical operators AND OR DEL etc.Historical log stores 10000 events plus 4000 active events in non-volatile memory standalone or network configuration.Clock in real time.Auto-programming lines with automatic recognition of the model of the devices.Decision algorithms for the alarm pre-alarm and faults.Automatic day night sensitivity change.Indication of the need to clean the smoke sensors.Programmable alarm threshold for all sensors.Walk-Test function by zone.

GBP 1772.89
1