265 results (0,14100 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis VSP-025 Filter Cartridge for VLP VLS VLC amp VLF Pack of 20

Vesda VSP-005 VLP VLS VLC amp VLF Filter

Vesda VSP-005 VLP VLS VLC amp VLF Filter

Vesda VSP-005 VLP VLS VLC VLF FilterThe VESDA replacement filter cartridge is used to replace filter cartridges in VESDA LaserCOMPACT LaserFOCUS LaserPLUS and LaserSCANNER detectors. One model fits all detectors.Importance of Changing the FilterThe filters used in VESDA detectors are key to the performance of the detector. VESDA filers remove dust contamination from the sampled air providing a clean air bleed to preserve the optics in the detection chamber. Like any other filter filters in VESDA detectors must be replaced regularly to ensure optimum efficiency.It is recommended that the filter is replaced in the VESDA VLC VLS VLP and VLF every two years to maintain the operational integrity of the detector you may want to consider replacing the filter more frequently if the detector is used in dusty or dirty conditions. Instructions on how to do this can be found in the replacement instructions in the download section below.Replacing the FilterBefore replacing the filter in your detector it may be necessary to advise any monitoring authorities that the detector may be offline for a short period.Ensure that the area surrounding the filter is clear of dirt and debris and remove the filter. Do not attempt to clean and reuse the filter VESDA filters are intended for single-use only. Once the new filter has been inserted the detector needs to be informed that a new filter has been installed.Key FeaturesEasy swap replacement filterFits VLC VLF VLP and VLS VESDA detectorsAvailable singly or in packs of 2090 mm x 63 mm x 30 mm 3.5 in. x 2.5 in. x 1.2 in.

GBP 69.64
1

Vesda Xtralis Flush Mount Sampling Point VSP-877

Vesda Xtralis Flush Mount Sampling Point VSP-877

Vesda Xtralis Flush Mount Sampling Point VSP-877Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling.It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards. Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions.It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis AspiratingSmoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitAccommodates several capillary tube sizes including 6 mm 8 mm 10 mm and to suit various regional requirementsAccommodates an optional Push-in Connect Adaptor for the Americas capillary tubing for increased robustnessFlush mount design provides less obtrusive installation and improved aestheticsStandard 2 mm 564 pilot sampling hole which can be drilled out up to 5 mm 1364 as per system design calculationsTapered sampling hole helps resist cloggingSnap-fit fascia conceals sampling hole which is easily removable to permit cleaning if requiredRoHSREACH compliant

GBP 22.57
1

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 DisplayThe VESDA-E VES can identify and monitor smoke density by individual sampling pipe sector which allows a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds Alert Action Fire 1 and Fire 2 per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.The VESDA-E is the most advanced reliable and flexible ASD system ever produced.Key FeaturesSector addressability for up to four sectors or zonesAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAuto Learn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 5292.54
1

Vesda Xtralis F-PC-3.5 Standard-Clip for ASD Pipework 3.5mm - Pack of 5

Vesda Xtralis F-PC-3.5 Standard-Clip for ASD Pipework 3.5mm - Pack of 5

Vesda Xtralis F-PC-3.5 Standard-Clip for ASD Pipework 3.5mm - Pack of 5A standard clip for aspirating holes 3.0mm in the colour orange.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure

GBP 21.32
1

Vesda Xtralis F-PC-HE-3.5 Freezer Clip for ASD Pipework 3.5mm - Pack of 5

Vesda Xtralis F-PC-HE-3.5 Freezer Clip for ASD Pipework 3.5mm - Pack of 5

Vesda Xtralis F-PC-HE-3.5 Freezer Clip for ASD Pipework 3.5mm - Pack of 5When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection. This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces.The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece. The pipe clips are also available in two formats Standard and Harsh Environment.Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air. This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installation Installation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressureMain ColourTab ColourInchMMOrangeOrange9643.5Please note The image is for illustrative purposes only.

GBP 46.27
1

Vesda Xtralis F-PC-2.5 Standard-Clip for ASD Pipework 2.5mm - Pack of 5

Vesda Xtralis F-PC-2.5 Standard-Clip for ASD Pipework 2.5mm - Pack of 5

Vesda Xtralis F-PC-2.5 Standard-Clip for ASD Pipework 2.5mm - Pack of 5A standard clip for aspirating holes in the colour red 2.5mmWhen installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure

GBP 21.32
1

Vesda Xtralis F-PC-HE-2.5 Freezer Clip for ASD Pipework 2.5mm - Pack of 5

Vesda Xtralis F-PC-HE-2.5 Freezer Clip for ASD Pipework 2.5mm - Pack of 5

Vesda Xtralis F-PC-HE-2.5 Freezer Clip for ASD Pipework 2.5mm - Pack of 5When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection. This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces.The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece. The pipe clips are also available in two formats Standard and Harsh Environment.Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air. This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installation Installation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressureMain ColourTab ColourInchMMRedRed6642.5Please note The image is for illustrative purposes only.

GBP 46.27
1

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Grey

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Grey

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - GreyThe Flush Mount Sampling Point patent pending provides a functionally and aesthetically improved alternative to the conical sampling point used in Xtralis Aspirating Smoke Detection ASD pipe networks.Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling. It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards.Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions. It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis Aspirating Smoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitFlush mount design provides less obtrusive installation and improved aestheticsTapered sampling hole helps resist cloggingRoHSREACH compliantPlease note This image is for illustrative purposes only

GBP 25.51
1

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Black

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - Black

Vesda Xtralis VSP-877-G Flush Mount Sampling Point Head Only - BlackThe Flush Mount Sampling Point patent pending provides a functionally and aesthetically improved alternative to the conical sampling point used in Xtralis Aspirating Smoke Detection ASD pipe networks.Unlike the conical sampling point the Flush Mount Sampling Point provides an easier and faster installation due to its unique design allowing the installation to be completed from one side of a ceiling. It incorporates text XTRALIS FIRE DETECION SYSTEM DO NOT PAINT complying with codes and standards.Designed for secure connection through push fit the sampling point accommodates the various regional capillary tube sizes 6 mm 8 mm 10 mm and commonly used with Xtralis ASD pipe networks making it deployable in all regions. It also accommodates an optional push-in connect adaptor kit VSP-878 for the Americas for increased robustness when used with larger diameter capillary tubing.Its elegant flush design blends in seamlessly into the installation providing considerably improved aesthetics.Key FeaturesSuitable for all Xtralis Aspirating Smoke Detectors providing a standard solutionUnique wing-lock arrangement permits installation from bottom side of ceiling which is ideal for fixed ceilings where access to the other side would be difficult or otherwise impossibleAdjustable wing-lock height to accommodate different ceiling panel thicknessesIncorporates text compliant with codes and standardsDesigned for secure connection through push fitFlush mount design provides less obtrusive installation and improved aestheticsTapered sampling hole helps resist cloggingRoHSREACH compliantPlease note This picture is for illustrative purposes only

GBP 25.06
1

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline Battery

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline Battery

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline BatteryEach emitter up to 7 generates 2 light beams in the UV and IR frequencies. These bundles are also encoded through a unique code recognized by the receiver. This approach allows the receiver to ignore any UV and IR light beams that come from sources other than emitters the typical interference problems generated by sunlight are thus overcome.Battery powered emitters last for 3 years.Emitter Size 208 mm x 136 mm x 96 mm. Certificate 3052011 EU - CPR.Open-area Smoke Imaging Detection OSID by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection OSID provides a cost-effective reliable and easy-to-install solution that overcomes typical beam detection issues such as false alarm incidents and alignment difficulties.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.Key FeaturesPatented dual wavelength UV IR particle detectionCMOS imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHigh resistance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m 492 ft. with minimal free space dia. 15 cm 5.85 inchApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floors

GBP 326.59
1

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to PeerThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the peer-to-peer model the host polls the HLI for information about devices on VESDAnet while the HLI sends unsolicited messages to the host. In this way both the HLI and host are responsible for supervising the communications link between them. In the peer-to-peer model the host can request and receive multiple messages from the HLI.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM42 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2443.61
1

Vesda Xtralis 128-015 Smoke Detector Pipe Label - Pack of 100

Vesda Xtralis 128-014-XTR Label Sampling Point Roll of 100

Vesda Xtralis REDSOC-10 PIP-002 25mm Jointing Socket Pack of 10