108 results (0,16561 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP2 2 Loop Expansion PCB ZP2-LB

Ziton 2010-2-PIB-8I Interface Printer Circuit Board with 8 Inputs

Ziton 2010-2-PIB-8O Interface Printer Circuit Board with 8 Outputs

Ziton 2010-2-DACT Digital Alarm Communicator Transmitter

Ziton ZP2-AF2 2 Loop Addressable Panel

Ziton ZP2-AF2 2 Loop Addressable Panel

Ziton ZP2-AF2 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 765.35
1

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZTThe ZP752-2 is a loop wired interface providing two conventional alarm circuits. It may programmed to operate from a single address a group or zone of devices or as a common output from any trigger device connected to the system.Power for the alarm circuits is supplied either from an external power supply unit or directly from the panels 24VDC supply via separate wiring. The ZP752-2 monitors its power supply and failure is reported to the main control panel automatically.On operation both sounder circuits are simultaneously activated. A red LED indicator is illuminated on the front of the unit to confirm operation.Fully monitored for open and short circuit faultsAny number of ZP752-2 units up to a max of 127 can be connected to the ZP loop. In systems complying with the recommendations of BS5839-1 where sounder response to the operation of a manual call point must be within 3 seconds up to 16 ZP752-2 output units assigned to the first 16 addresses on each loop can be operated within the time period.Wiring is monitored for open and short circuit faults by means of end of line resistors. Faults are automatically reported to the control panel together with the address of the ZP752-2 interface. An amber LED indicator on the front of the moulding is illuminated to indicate the fault condition.First and second fix installationDesigned for first and second fix installation the unit comprises an open back box containing all wiring terminals together with a front plate enclosure of high impact plastic housing all electronics printed circuit boards and selection switches. The two parts simply plug together prior to system completion.All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesTwo monitored sounder circuitsSupport for 3s response from manual call pointsAddressable - connects to ZP loopProgrammable for continuous or pulsed output

GBP 98.81
1

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit BoardThe 2010-2-PIB Peripherals Interface Board is an accessory of the small to medium size intelligent addressable life safety control systems. In total there are 4 variants of this board. The 2010-2-PIB is the most extended variant of the range and provides ways to interface other electronic equipment on site.The board can be plugged directly on the front of the main board inside the big size control panel variants on top of the new release 3 chassis. No additional wiring is required. You can use the pluggable connectors to make your connections to the field wiring. Connect an external power supply to the board directly to reduce the load of your system.The 2010-2-PIB Peripherals Interface Board provides eight inputs and outputs and four relay outputs for compatible control panels. The board is designed to support German marketplace requirements in control panels operating in VdS 2540 mode and provides an interface to the IFAM System 3000 network fire brigade equipment and other regional control and indicating equipment and devices. The board can be powered from the control panel or from an external power supply providing 24 VDC to each of the supervised outputs. Inputs and outputs excluding relay outputs are supervised for short circuit and open circuit faults.Key Features8 supervised inputs8 supervised outputs4 relay outputsOption to externally powerInterface to the IFAM System 3000 networkOperating in VdS 2540 modePluggable connectors

GBP 182.74
1

Ziton ZP755HAV-2 Addressable Sounder Beacon Red

Ziton ZP755HAV-2 Addressable Sounder Beacon Red

Ziton ZP755HAV-2 Addressable Sounder BeaconThe ZP755HAV-2R is a RED ZP7 Series addressable sounder with visual indicator for use with Ziton addressable fire detection systems. Disability legislation increasingly requires visual alarm signals to be employed to ensure equal response from people with hearing impairment. ZP755HAV-2 devices are perfectly suited for this application and any application involving high levels of background noise. It provides both audible and visual warnings from a single addressable loop wired unit.The ZP755HAV-2 minimises the number of installation points required throughout a building significantly lowering the capital value of equipment and the loop wiring costs of the completed system. Installation time and costs are further reduced as the device plugs directly into a first fix base eliminating the need for any internal connections.Self test facilityHigh efficiency acoustic design and a low current LED visual element enables up to 20 sounder beacons to be connected to a 1 km loop of 1.5mm cable with a wiring run of 50 m to the first device. The range features a unique self test facility - automatically activated during routine sounder testing. A built in microphone circuit measures sound output and automatically signals the sounder address and location to the control panel should the output test fail.In systems where loop lengths or current requirements are excessive the ZP755HAV-2 can be powered directly from an external power supply.Range of sound outputsContinuous intermittent and two-tone audible outputs are available from which any combination can be chosen to provide alert and evacuate two stage alarms. All sound types comply with BS5839 Part 1 recommended frequencies.The ZP755HAV-2 produces a sound output of up to 92 dBA. A volume control is included for areas where a reduced sound output is required.Moulded in high impact thermoplastic the sounder beacon is available in either red with red lens or white with clear lens both illuminating red.Key FeaturesPowered directly from the ZP loopUp to 20 devices directly on the loop wiringLow current LED based visual elementHigh efficiency sound gun transducerPlug in base no direct wiring connectionsEN543 Approved and CPR certified

GBP 86.34
1

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone InterfaceThe A70E-2 zone interface is fully loop powered and enables existing or new conventional zones to be interfaced to an analogue system allowing all areas of a site to be controlled by the ZP analogue panel. Through its interface each zone is assigned a unique address. Zones are monitored for fire and fault conditions and status is reported to the ZP control panel every 2 seconds. Zones of up to 15 Ziton Z600 conventional trigger devices can be connected to the interface with a maximum of 127 interface units installed on each ZP loop.The A70E monitors its conventional zone wiring for open and short circuit faults via end of line resistors supplied with the unit. When detectors are installed with Z6-BS5 bases the interface maintains complete operation of all other zone devices should a detector from within the zone be emoved from its base. Clear visual indication is shown on the front of the A70E moulding for alarm red LED and fault amber LED.Deriving power directly from the loop wiring and with a low current consumption in addition to zonal connection the interface has many system applications ranging from the interface of equipment for hazardous areas to the operation of magnetic door retainers via an interposing relay and linear beam detectors. Housed in low profile mouldings the interface is designed to clip directly onto a standard DIN35 rail fixing or be installed in a SMB-DIN100 box one unit capacity or a SMB-DIN200 box two unit capacity. In systems where numerous interfaces are installed or current requirement is excessive the A70E can be powered from an external power supply.Key FeaturesInterfaces up to 15 Ziton Z600 conventional devices to the ZP loopAddressable - reports status every 2 secondsMonitors conventional zone wiringDetector removal monitoring with Z6-BS5 basesDIN35 rail mountedUp to 127 conventional zones interfaced to each ZP loop with external PSU

GBP 114.34
1

Ziton ZP2-AF2-S 2 Loop Addressable Panel

Ziton ZP2-AF2-S 2 Loop Addressable Panel

Ziton ZP2-AF2-S 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 780.25
1

Ziton ZP2-AF2-P 2 Loop Addressable Panel

Ziton ZP2-AF2-P 2 Loop Addressable Panel

Ziton ZP2-AF2-P 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 981.05
1