381 results (0,15185 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton AACU-PCC Alarmline II Analogue LHD PC Software with USB Cable

Ziton ZP3-PR1 Optional Printer Kit

Ziton ZP3-PR1 Optional Printer Kit

Ziton ZP3-PR1 Optional Printer KitThe ZP3-PR1 is a 24 character dot matrix printer which can be fitted to the front door of the ZP3 control panel. The kit comprises a printer module printed circuit driver board and the necessary mounting hardware to fit the unit.The printer is software controlled with operating parameters simply configured in the fire alarm system set up programme to respond to a comprehensive range of system events. Fire alarms faults panel operations and activated outputs are automatically printed out as they occur with facilities to suppress any event category - for example print fire alarms suppress disablements.Report and archive printingPrintouts of selected sections of the ZP3 panel archive based upon the last 1000 events can also be produced by date and time on demand. A comprehensive series of reports detailing system operation or maintenance information can be printed ranging from system configuration and input output mapping through to sensor analogue levels and servicing requirements.Service reports can include individual sensor status listing point type sensitivity zone and service and near service condition.Easily installed moduleEasily installed the self-contained printer module is clamped to the rear of the panel door in line with an aperture provided as standard on all ZP3 control panels. Data connections are by means of ribbon cable with power supply provided by plug and socket arrangement.The printer unit includes a paper feed control and a no paper indication when the paper roll is exhausted. The printer module is designed with front access - through which paper roll and print ribbon can be replaced without opening the control panel enclosure.The ZP3-PR1 printer is part of the range of optional facilities which can be added cost effectively to any ZP3 control panel in order to provide extra features that may not be a requirement of every system.Key Features64 character ASCII upper and lower case printerEasily installedOperation and maintenance reportsPaper roll and ink ribbon cartridge replaced without opening panel

GBP 657.94
1

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 Loop

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 Loop

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 LoopThe 2-loop ZP2-F2-FB2-PRT Addressable fire panel with fire brigade controls and printer is a good choice for small to mid-sized addressable applications. Its main controls are clearly yet discreetly highlighted with the focus on the centrally located Jog Dial. With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits both building owners and life safety system installers.Key FeaturesThermal printer with paper replacement from the front2 loops expandable to 4 with up to 512 zones with Fire Brigade Fire Protection controls and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with generous text spaceAuto configuration setup wizard and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dial with 4 soft buttons for simple and intuitive user controlPleasing design with paintable synthetic doorEasily removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 72 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 1241.38
1

Ziton ZCC868 Radio Hub Configuration Cable amp Programming Software with PC Lead

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large CabinetThe Ziton ZP2-AF2-PRT-99 addressable fire alarm panel with printer has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key FeaturesBuild-in thermal printer with paper replacement from the front2 High Power Loop expandable to 4 with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1242.37
1

Ziton AAI-0100 Interposing Cable

Ziton AAI-0100 Interposing Cable

Ziton AAI-0100 Interposing CableThe AAI-0100 is a non-detecting interconnection cable for use with linear heat detection cable and is supplied in 100m lengths. It is used in conjunction with analogue or digital linear heat detection cable where the interface unit and the protected area is not at the same location thus this cable is connecting the interface unit with the detection cable which is located in the protected area.InstallationThe ACA-JBW junction box must be used for the connection between the linear heat detection cable and the non-detecting cable. This is crucial to ensure that environmental conditions and materials dont affect the connection which in turn will affect the detection capability of the system.ApplicationIn some applications due to site requirements or layout it might not be possible to install the linear heat detection interface in or next to the protected area. As a result it will be installed at a different location with the requirement to connected the linear heat detection cable in the protected area with the remote interface unit.The non-detecting interconnect cable is specifically designed for this scenario. It ensures that detection is only active in the protected area and not in the area in between the interface unit and the protected area. Additionally it offers a cost-effective alternative to using more expensive linear hear detection cable.Key FeaturesNo detection propertiesFor use with analogue and digital linear heat detection systemsCost-effective

GBP 301.19
1

Ziton 1-B6782-170 Retractable Cable 30m

Ziton ACA-JBW Junction Box IP6566 with Cable Glands amp Terminals

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit BoardThe 2010-2-PIB Peripherals Interface Board is an accessory of the small to medium size intelligent addressable life safety control systems. In total there are 4 variants of this board. The 2010-2-PIB is the most extended variant of the range and provides ways to interface other electronic equipment on site.The board can be plugged directly on the front of the main board inside the big size control panel variants on top of the new release 3 chassis. No additional wiring is required. You can use the pluggable connectors to make your connections to the field wiring. Connect an external power supply to the board directly to reduce the load of your system.The 2010-2-PIB Peripherals Interface Board provides eight inputs and outputs and four relay outputs for compatible control panels. The board is designed to support German marketplace requirements in control panels operating in VdS 2540 mode and provides an interface to the IFAM System 3000 network fire brigade equipment and other regional control and indicating equipment and devices. The board can be powered from the control panel or from an external power supply providing 24 VDC to each of the supervised outputs. Inputs and outputs excluding relay outputs are supervised for short circuit and open circuit faults.Key Features8 supervised inputs8 supervised outputs4 relay outputsOption to externally powerInterface to the IFAM System 3000 networkOperating in VdS 2540 modePluggable connectors

GBP 182.74
1

Ziton 2010-2-PIB-8O Interface Printer Circuit Board with 8 Outputs

Ziton 2010-2-PIB-8I Interface Printer Circuit Board with 8 Inputs

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal PrinterOverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals Compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1221.61
1

Ziton AD88N-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon

Ziton AD88N-1000 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon

Ziton AD88N-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon