1.962 results (0,14801 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cranford Controls IS-MC1-R Intrinsically Safe Minialert SounderBeacon Red Body Red Lens

Baldwin Boxall Omnicare Fire Tel Red Push Door CW Beacon BVOCFB

Baldwin Boxall Omnicare Comb Red PDoor CW Beacon BVOCCB

Vimpex Intrinsically Safe Sounder Red IS-D105-R

Morley EVCS-HSA-RS-D Digital Type A Outstation - Red Surface Mount

Baldwin Boxall Omnicare Combined Red Locking Door CW Beacon BVOCCLB

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCFThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCF red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFS.Push catch door slot lock version available BVOCFL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 540.70
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFL red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFSL.Slot lock door push catch version available BVOCF.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 576.98
1

Apollo XP95 Intrinsically Safe Red Manual Call Point MEDC Style 55000-961APO

Baldwin Boxall Omnicare Combined Red Fire Telephone and Green DRS Unit BVOCCGCP

Baldwin Boxall Omnicare Fire Tel Red Lock Door CW Beacon BVOCFLB

Baldwin Boxall Omnicare Fire Tel Red Lock Door CW Beacon BVOCFLB

Baldwin Boxall Omnicare Fire Tel Red Lock Door CW Beacon BVOCFLBFire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has acombined outstationwhich includes both a fire telephone and a disabled refuge unit in the same enclosure.Other outstations available include steward telephones and disabled toilet alarms.Omnicare fire telephones are powered from the ring circuit and have the following featuresRed or stainless-steel finishRugged red handset with T-Coil hearing aid compatible earpiece and loudspeakerHands free useFull duplex speech digital audioDoor latch initiates callPush catch or slot lockable door andor beaconConference facility via master control panelSurface mountable optional flush mount bezel availableWired in aloop configurationusing fire rated enhanced four-core cable

GBP 677.68
1

Zeta ETS-CPR Emergency Telephone System Control Panel Red Handset

Patol Infra-Red Heat Sensor 5610SS Stainless Steel 316 ATEX Approved 722-009

Patol Infra-Red Heat Sensor 5610SS Stainless Steel 316 ATEX Approved 722-009

Patol Infra-Red Heat Sensor 5610SS Stainless Steel 316 ATEX ApprovedCompressed Air Lens Clean Purging cw Mounting Bracket 722-009The 5000 Series is an early warning infra-red heat sensor which can trigger at temperatures as low as 100C when monitoring materials being transported on conveyor systems before they have reached the ember or flame condition.Its unique dual detector enhanced Infra-red monitoring has been created to detect black heat. Black body emissions occur for all material the sensor is designed to detect a change in these emissions even at relatively low temperatures when the material moves through its field of view.The 5610SS is specifically designed for hazardous areas and is ATEX approved.Air purging from a compressed air feed is used to maintain a lens cleaning system that ensures the prevention of dust settling on the sensor window.The 5610SS incorporates within the unit a user programmable SIL switch. Option selection includes detector sensitivity settings automanual reset sequence selection and singlecoincidence voting from the two individual internal detectors for the alarm trip shutdown outputs.Key FeaturesCompressed air lens clean purgingStainless steelDetection of hazards at temperatures below flame point including both embers and buried hot spotsATEX approvedTwin high integrity detection circuit channels for maximum reliabilityTwo wire operation - Can be powered by direct connection to standard fire trigger circuits or addressable loop interfaceSingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVolt free relay contact output operation selectable as standardFault Monitored with Test Reset push ButtonsField Programmable

GBP 5770.80
1

Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012

Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012

Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012The 5000 Series is an early warning infra-red transit heat sensor which can trigger at temperatures as low as 100C when monitoring materials being transported on conveyor systems before they have reached the ember or flame condition.Its unique dual detector enhanced Infra-red monitoring has been created to detect black heat. Black body emissions occur for all material the sensor is designed to detect a change in these emissions even at relatively low temperatures when the material moves through its field of view.Air purging from a mains operated Air Purged Blower APB feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window.The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5410 incorporates within the unit a series of user programmable SIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the two individual internal detectors for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an aux. fault input common fault output contact.Key FeaturesDetection of hazards at temperatures below flame point including both embers and buried hot spotsAir purged system for dusty environments with air pressure monitoringTwin high integrity detection circuit channels for maximum reliabilityTwo wire operation - Powered by direct connection to standard fire trigger circuits or addressable loop interfaceSingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVolt free relay contact output operation selectable as standardFault Monitored with Test Reset push buttonsField Programmable

GBP 3642.24
1

Cooper Menvier TA16-RS Type A Outstation - Red - Surface Mount