23 results (0,16755 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zehnder ComfoAir Flex 250 MVHR

Zehnder ComfoAir Flex 250 MVHR

Zehnder ComfoAir Flex 250 MVHR Product Part Number Zehnder ComfoAir Flex 250 - 471234220 Zehnder ComfoAir Flex 250 with pre-heater - 471234230 Decription Zehnder ComfoAir Flex is a ventilation unit that has been specially developed for apartments and smaller homes, where living space is a valuable resource and needs to be wisely planned. The compact design fits seamlessly in suspended ceilings without sacrificing outstanding performance. Zehnder ComfoAir Flex is equipped with the quietest fan technology on the market and reduces noise levels to a minimum even during full operation. A custom-made heat exchanger and scroll housing ensure a high level of heat recovery while keeping energy consumption low and efficient. ComfoAir Flex 250 The Zehnder ComfoAir Flex 250 has been developed as an ideal solution for apartments and small homes whereefficient use of space is important. Installation within a suspended ceiling is possible, even in small spaces, thanks toits compact design with minimal dimensions and rotatable spigots. It contains features such as its integrated Wi-Ficonnection with app control, automatic true summer by-pass, high heat recovery efficiency and upgradable high gradefilters providing a comfortable, healthy and energy-efficient indoor climate. Key Benefits Wi-Fi enabled as standard for use with the ComfoControl app for IOS or Android. Left or right hand configuration through software alone, no mechanical alteration required. 100% full and filtered modulating summer bypass. Rotatable spigots for flexibility on duct connections. Commissioning wizard for a quick and simple set-up process. Flow control to maintain commissioned flow rates. Adaptive comfort technology. Automatic passive temperature boost in summer. Humidity boost continuously monitors the humidity level within the home and looks for a man-made spike before boosting the unit, irrespective of distance or dilution. Double dry siphon included to enable an easier installation. Tool free filter access. Volt free contact boost capability. 0-10V BMS input. Fire shutdown contact. Remote access. Internal pre-heater option. ISO Coarse (G4), ISO ePM10 (M5) and ISO ePM1 (F7) filter options. Passive House certified.

GBP 2515.26
1

Special Offer Panasonic 3Kw HP - All in One Kit of cylinder and heat pump R32 EX-DISPLAY

Quiet-Vent Metal Adaptor for Distribution box

Metal Reducers

Metal Reducers

Metal Reducers Product Part Number 100-80mm Short Reducer - R10080M 125-100mm Short Reducer - R125100M 150-100mm Short Reducer - R150100M 150-125mm Short Reducer - R150125M 160-100mm Short Reducer - R160100M 160-125mm Short Reducer - R160125R 160-150mm Short Reducer - R160150M 180-125mm Short Reducer - R180125M 180-150mm Short Reducer - R180150M 180-160mm Short Reducer - R180160M 200-100mm Short Reducer - R200100M 200-125mm Short Reducer - R200125M 200-150mm Short Reducer - R200150M 200-160mm Short Reducer - R200160M 200-180mm Short Reducer - R200180M 250-150mm Short Reducer - R250150M 250-180mm Short Reducer - RC250180 250-200mm Short Reducer - R250200M Description Metal reducers are constructed of high quality durable galvanised metal Manufactured without seals Male spigots, these metal reducers will fit inside round metal ducting. Made in the UK Perfectly suited for ducting your ventilation system, kitchen extractor fan, bathroom fan or in-line extract fans Can be used to connect long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and heat recovery systems. Compatibility Compatible with most other lead manufacturers for galvanised metal ducting Performance Solid rigid ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or aluminium duct. Suitable to use in compliance with Part F Building Regulations. Installation

GBP 8.24
1

Flexible Circular Connector

Vent Matika Duct Mounted Hot Water Heater Range

Mitsubishi Lossnay-VL250 Units

Mitsubishi Lossnay-VL250 Units

Mitsubishi Lossnay-VL Units Product Part Number Mitsubishi Lossnay VL-250 (L) wall mounted residential MVHR with bypass and digital controller - LEFT - VL-250CZPVU-L-E Mitsubishi Lossnay VL-250 (R) wall mounted residential MVHR with bypass and digital controller - RIGHT - VL-250CZPVU-R-E Description The Mitsubishi VL-250 is a quality unit with the advantage of a unit mounted controller with 5 years part warranty and provides a maximum flow rate of 250m3/hr suitable for a house up to 150 m2 floor area with up to 3 kitchens & bathrooms BPC Ventilation are the largest independent MVHR specialists and supply this unit with up to a 5-year parts warranty* and lifetime technical support on our top-quality systems Filtration 2 x G3 filters are fitted to the unit that are easy and inexpensive to replace Optional ePM2.5 50% to air supply Optional NOX 90% filter to air supply CONTROL OPTIONS The Mitsubishi VL units are controlled by one of the following: Control Via Unit mounted digital controller 0-10v sensor Volt free contacts Additional external sensors achieving on-demand ventilation Switched live signal from remote switches Optional wall controller (P-RCC-E) Optional Wi-Fi integration to phone (MAC-5671F-E)   Optional Wi-Fi with additional accessory - MAC-5617F-E   Summer By-Pass The VL range of units have a 100% summer by-Pass If the indoor temperature Intake exceeds 25°C and the outdoor temperature is within comfort zones the summer by-pass is opened automatically to help provide a comfortable indoor temperature Heat Exchanger This unit has a high-quality PVC counterflow heat exchanger with up to a 90% thermal efficiency protected with high-capacity filters on each side The heat exchanger is easy to remove for maintenance and any accumulated condensation is easily dispersed via a drain at the bottom of the unit   Frost Protection In the event of the intake air temperature at the unit dropping below the predetermined set point (-3°C as standard) the supply fan will reduce to minimum speed, once the temperature rises above the set point the fan will return to its commissioned speed. Frost protection will only activate after ten days of continuous run time. Orientation The Mitsubishi Lossnay VL units can be right or left-handed and correct orientation should be checked before purchase Construction Manufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency Mounting The units are wall mounted as standard and are supplied with a wall bracket

GBP 1001.45
1

FLY 152mm Fireproof Insulated Flexi Duct x 10m

Zehnder Caladair Miniblue Compact Box Fan

FLY 127mm Fireproof Insulated Flexi Duct x 10m

Vent Matika Duct Mounted Cold Water Cooler/Heater Range

Vent Matika EKA standard duct heater

Vent Matika EKA standard duct heater

Vent Matika EKA standard duct heater Description The Vent Matika EKA range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost. The Vent Matika EKA standard range have no integrated control BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, KEY FEATURES – Vent Matika EKA standard heater No integrated control Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options No integrated control feature on this unit and we recommend connection to a EKR electric heater control and sensors or 3rd party control panel with fused supply  (electrician installation recommended) Overheating Protection The EKA has two overheat protection thermostats installed in the electrical circular heater The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-250-3.0 Optional Accessories EKR 6.1 - electric heater controller for single phase electric heaters up to 6 kw. Controls by supply* or room temperature. Has an internal temperature sensor in casing, an additional TJ-K10K duct mounted supply air temperature sensor is also required for operation in both modes.  BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items Largest independent MVHR suppliers Lowest cost on full systems guaranteed Inhouse design Team Inhouse certified training Largest range and stock available Worldwide delivery options MVHR Solutions available from Value to Prestige housing

GBP 121.73
1

Special Offer Vectaire Maxi AT BY LCDRH Model

Special Offer Vectaire Maxi AT BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1560.00
1

Special Offer Vectaire Maxi BY LCDRH Model

Special Offer Vectaire Maxi BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1320.00
1

Komfovent Left Hand R250F Rotary wheel lay flat horizontal floor unit

Komfovent Left Hand R250F Rotary wheel lay flat horizontal floor unit

Description Komfovent R250 F Left Hand 1156589 Komfovent R250 F Right Hand 1156591 The Komfovent Domekt R-250-F heat recovery unit is a high-quality ceiling or floor mounted rotary wheel unit suitable for new houses up to 150m2 that has advanced Wi-Fi controllability and are suitable for very cold climates of down to -30° This unit has an (A) energy rating BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key features- Komfovent R250 F Interactive Wi-Fi Smart control Passive house approved C6M Digital controller* Next Generation rotary heat exchanger Suitable for home sizes up to 150m2 Airflow rate @100Pa - 250m3/h Optional direct connection to kitchen cooker hood Super Quiet with insulated construction No drain or pre-heater required Highly efficient EC fans 100% summer bypass M5 filtration ‘A’ energy rating High heat recovery efficiency of up to 86%. On demand control via optional room or duct sensor options Fireplace and holiday settings CAV -VAV-DCV airflow control Plug and play easy installation Optional Humidity control Optional F7 filtration Controllability The Domekt units feature an integrated smart control system allowing you to control your system without constant adjustments via the Komfovent Home application on your home computer or mobile device, the unit also has an additional hard wired digital remote control if required App Control Wall controller (optional) 8 preset modes. Intelligent energy saving algorithms. Automatic air quality control with optional AQ sensor. Extensive weekly schedule. External Control Ability to control via a web browser for remote monitoring and repair Integration into a smart home management system. (BMS) parameters by connecting additional sensors. Optional wall controller 0-10v and 0v connections Optional boost switch Optional humidity sensor (duct mounted)   BMS Control Implemented BACnet and Modbus protocols enable simple connection into Building Management System as a result whole buildings engineering systems can be controlled at a single access point. Construction Domekt heat recovery units are double protected from corrosion. The units are constructed of galvanised steel with a powder coated finish (RAL9003) and EPP internal casing, The airtight doors are 50mm thick  with thermal locks Motors The fan motors are low energy EC fans of A+ rating and are protected from humidity and dust as well as being equipped with long-life bearings Filtration 2 x G5 filters are fitted to the unit that are easy to replace Optional F7 to air supply Summer By-Pass The Komfovent range of units have a 100% summer by-Pass If the indoor temperature Intake exceeds 25°C and the outdoor temperature is within comfort zones the summer by-pass is opened automatically to help provide a comfortable indoor temperature Low Noise Levels With airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet Heat Exchanger Frost Protection There is no condensation drain and Frost protection is not required unless below - 20° Orientation The units can be right or left-handed and correct orientation should be checked before purchase Construction Manufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency

GBP 2668.14
1

Vent Matika EKA NI duct heater

Vent Matika EKA NI duct heater

Vent Matika EKA NI duct heater Description The Vent Matika EKA NI range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost. The EKA NI is controlled by a room mounted set point controller BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, KEY FEATURES – Vent Matika NI heater Controlled via room mounted set point controller Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified CONTROL OPTIONS The EKA NV has a wall mounted setpoint controller connected to a duct mounted temperature sensor at the heater   When connected, the heater is working according to the duct sensor, and the supply air temperature sensor limits supply air temperature – +15°C…+40°C. Overheating Protection Two overheat protection thermostats are installed in the electrical circular heater EKA. The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Installation Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-NI-100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-NI-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-NI-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-NI-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-NI-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-NI-250-3.0 Optional accessories PTC Airflow sensor– Unit mounted sensor for electronic protection from insufficient airflow. The heater is only allowed to work if the airflow velocity is 1,5m/s or higher PS Differential Pressure Switch – a unit mounted pressure switch that provides mechanical protection against loss or insufficient airflow. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.   (Note -due to required velocity the PTC or PS option may not work on some smaller domestic MVHR or MEV systems with low airflow rates) PTC/PS – Sensor for minimum air velocity detection and diff. pressure switch for air flow detection PTC/K – Sensor for minimum air velocity detection and contactor for overheating protection 2NTC – 2 sensors for the air temperature measuring PTC/2NTC – Sensor for min. air velocity detection and 2 sensors for the air temperature measuring By ordering the PS, an internal contactor for power supply is added to the heater as well. BPC Support We don’t sell boxes; we provide a service that few can match Free

GBP 291.68
1

Vent Matika EKA NIS duct heater

Vent Matika EKA NIS duct heater

Vent Matika EKA NIS duct heater Description The Vent Matika EKA NIS range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost The Vent Matika EKA NIS range of electric duct heaters are controlled by an external 0 to 10v DC signal from a compatible MVHR unit or independent controller BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key Features Controlled via a 0 to 10v DC signal Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options 0-10v sensor from a compatible MVHR unit or independent controller will allow 0-100% control of the heaters power Overheating Protection Two overheat protection thermostats are installed in the electrical circular heater EKA. The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Installation Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-NIS 100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-NIS-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-NIS-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-NIS-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-NIS-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-NIS-250-3.0 Optional accessories PTC Airflow sensor– Unit mounted sensor for electronic protection from insufficient airflow. The heater is only allowed to work if the airflow velocity is 1,5m/s or higher PS Differential Pressure Switch – a unit mounted pressure switch that provides mechanical protection against loss or insufficient airflow. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.   (Note -due to required velocity the PTC or PS option may not work on some smaller domestic MVHR or MEV systems with low airflow rates) PTC/PS – Sensor for minimum air velocity detection and diff. pressure switch for air flow detection PTC/K – Sensor for minimum air velocity detection and contactor for overheating protection 2NTC – 2 sensors for the air temperature measuring PTC/2NTC – Sensor for min. air velocity detection and 2 sensors for the air temperature measuring By ordering the PS, an internal contactor for power supply is added to the heater as well.  BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items Largest independent MVHR suppliers Lowest cost on full systems guaranteed Inhouse design Team Inhouse certified training Largest range and stock available Worldwide delivery options

GBP 195.38
1

Vent Matika EKA NV duct heater

Vent Matika EKA NV duct heater

Vent Matika EKA NV duct heater Description The Vent Matika EKA NV range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost. The EKA NV is controlled by a duct temperature sensor and unit mounted set point controller BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key Features Controlled via unit mounted set point controller Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options The EKA NV unit uses a duct mounted temperature sensor and is controlled via the set point potentiometer on the top of the heater casing. Overheating Protection Two overheat protection thermostats are installed in the electrical circular heater EKA. The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Installation Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-NV-100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-NV-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-NV-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-NV-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-NV-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-NV-250-3.0 Optional accessories PTC Airflow sensor– Unit mounted sensor for electronic protection from insufficient airflow. The heater is only allowed to work if the airflow velocity is 1,5m/s or higher PS Differential Pressure Switch – a unit mounted pressure switch that provides mechanical protection against loss or insufficient airflow. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.   (Note -due to required velocity the PTC or PS option may not work on some smaller domestic MVHR or MEV systems with low airflow rates) PTC/PS – Sensor for minimum air velocity detection and diff. pressure switch for air flow detection PTC/K – Sensor for minimum air velocity detection and contactor for overheating protection 2NTC – 2 sensors for the air temperature measuring PTC/2NTC – Sensor for min. air velocity detection and 2 sensors for the air temperature measuring By ordering the PS, an internal contactor for power supply is added to the heater as well.   BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items

GBP 291.68
1