129 results (0,17228 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Drayton Wiser Electrical Heat Switch

Mitsubishi VL100EU5-E Lossnay Wall Mounted Single Room MVHR

Drayton Wiser Remote Temperature Sensor

Drayton Wiser Room Thermostat

Eco Air HLC DMEV 100mm wall fan with Humidity, Timer , Backdraft 17l/s

Vent-Angel Ventilation Fire Safety Unit

Vent-Angel Ventilation Fire Safety Unit

Vent-Angel Ventilation Fire Safety Unit Product Part Number Vent-Angel Fire Safety Unit - QV-VA-21 Description The Vent-Angel is suitable for domestic homes and apartments and connects to any domestic fire alarm and will in the unfortunate event of a fire will remove the power supply to any type of Ventilation unit. The Vent-Angel unit can also control mains powered fire dampers, Purge fans or other devices The Vent -Angel is simple to install and comes complete with a discrete wall mounted control panel to test and reset the system. Why Use a Vent-Angel If a fire breaks out there is a possibility that any system that supplies fresh air could further cause the fire to intensify and spread. If even a small fire breaks out the smoke will enter the ventilation unit’s ductwork that could be very costly to remove any contaminants and smell. Control Panel The Vent-Angel includes a Test / Rest switch plate which would be mounted remotely in a location that has easy access (i.e. Hallway, Utility room), the switch plate also has LED operational indication. i.e. the Test push button with be illuminated Green under normal running conditions and the Reset push button will be illuminated Red in the event of a fault. The Test / Reset switch plate will also allow the system to be tested by pushing the TEST button. (It is recommended that this test is carried out twice yearly), to Reset the system press the RESET button, this action is also required if the system has been activated. Please ensure all Smoke/Fire Alarm issues have been resolved before activating the Vent Angel system. Contents: 1 x Vent Angel unit 1 x Vent Angel Test/Reset switch plate 1 x 15m length of 9 core YY cable 1 x 4mm O ring crimp 2 x Lockable Glands (FUW optional Fire Damper / Purge unit)

GBP 204.00
1

Zehnder Caladair Diablo Twin Smoke Exhaust Inline Unit

Xpelair C4TSR X-078346

Special Offer Vectaire Maxi AT BY LCDRH Model

Special Offer Vectaire Maxi AT BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1560.00
1

Special Offer Vectaire Maxi BY LCDRH Model

Special Offer Vectaire Maxi BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1320.00
1

Heatmiser UH8 230v 8 Zone Wiring Centre

Heatmiser UH8 RF 230v 8 Zone Wiring Centre

Zehnder ComfoAir 160

Zehnder ComfoAir 160

Zehnder ComfoAir 160 Product Part Number Zehnder ComfoAir 160 - CA160-GB Zehnder ComfoAir 160 Luxe - CA160LUXE-GB Zehnder ComfoAir 160 Luxe with pre-heater - CA160LUXEPH-GB Description The Zehnder ComfoAir 160 can be ceiling or wall mounted and suitable for properties up to 100m2 Available in two versions ComfoAir 160 – controlled by optional 3-speed switch ComfoAir 160 Luxe – controlled by optional digital controller or RF controllers Sap Appendix Q listed with (A+) energy rating and is Passive house approved BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems Key features Suitable for home sizes up to 100m2 85% heat recovery efficiency. 100% full and filtered modulating summer bypass. Left- or right-hand configuration on same unit Luxe has digital or RF controller options Passive house Approved 100% variable AUX speed for use as a way mode, medium speed or purge boost. BMS compatibility option. Volt free contact G4 filtration Tool free filter access. SAP Appendix Q listed Controllability The Zehnder ComfoAir units have an optional selection of boost switches and room sensors for demand controller ventilation Inputs Volt free contact boost capability. 240v switched live capability Wall controllers (optional) ComfoAir 160 controllers Comfo Control Basic The Zehnder CCL is a three-position switch designed to enable the user to manually select the desired ventilation systems flow rate Comfo Control Basic LED The Zehnder CCL is a three-position switch designed to enable the user to manually select the desired ventilation systems flow rate and provide system Maintenance notification ComfoAir 160 Luxe controllers Comfo Switch C67 Led controller that allows you to adjust speed and view service alerts  Comfo Control RFZ 3 Speed wireless controller (will only operate with the use of the RF-PCB) Comfo Control RFZT wireless timer controller of 10min to 90min (will only operate with the use of the RF-PCB) RF-PCB The Zehnder RF-PCB enables the CCRFZ (655 000 755) controller to be used with the ventilation system without the need for the Comfo Sense C67. Room Sensors 12V 0-10V RH sensor The Zehnder 12V 0-10V remote humidity sensor enables a signal to be sent to the ventilation system to control the corresponding flow rate. 12V 0-10V CO2 sensor The Zehnder 12V 0-10V remote CO2 sensor and combined three position switch is designed to enable the user to manually select the desired ventilation systems flow rate based on the visual air quality indicator, or automatically adjust the unit relevant to the CO2 level. Zehnder AQR The Zehnder AQR remote air quality sensor enables a signal to be sent to the ventilation system to automatically place the unit into a higher flow rate. Key Benefits Set activation level covering a range of pollutants such as hydrogen, CO, methane, ethanol and isobutane Adjustable overrun timer between 2-40 minutes Zehnder PIRR The Zehnder PIRR remote passive infra-red movement sensor enables a signal to be sent to the ventilation system to automatically place the unit into a higher flow rate. Key Benefits Senses movement up to 7 m away Adjustable overrun timer between 2-40 minutes Zehnder HHR The Zehnder HHR remote humidity sensor enables a signal to be sent to the ventilation system to automatically place the unit into a higher flow rate. Key Benefits Set humidity activation between 30-90% relative humidity Adjustable overrun timer between 2-40 minutes

GBP 2349.56
1