Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery PackThe ZR451-3 is a wireless 868 MHz single channel inputoutput unit. It provides a method of interfacing a supervised input or potential free output signal into and out of the fire detection and alarm system in areas where the installation of system wiring is not an option.The systemThe ZR451-3 communicates with the main control panel via a hardwired radio loop module that can be installed anywhere on the ZP loop. When the input gets an alarm signal it passes it via the radio loop module to the main fire control panel where it is processed. The output of the interface provides volt free change over contacts for connecting ancillary equipment and is programmed separately activated individually on in a group.High intensity LED indicators positioned on the ZR451-3 may be illuminated by a manually activated push button to identify when the interface has operated providing clear identification of the signal source.Installed as part of a ZP addressable system up to 127 line devices sensors call points or interface units may be connected to each of the control panel loops. Each wireless device is assigned its own IDENT address with which the main control panel communicates with it providing the same system facilities as directly wired devices.UsageAs an input the ZR451-3 may receive signals from other alarm equipment e.g. beam detectors aspiration detectors etc. Used as an output the unit switches equipment controlled by the fire detection system e.g. air conditioning systems magnetic door release units etc. Both input and output facilities are available from the same unit and may be operated simultaneously or individually as programmed at the fire control panel.Power supplyThe ZR451-3 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. The ZR451-3 features battery condition monitoring and reporting.Key FeaturesAddressable inputoutput interface unitWire free activationVolt free relay outputMonitored input for fire and faultTwo way radio communication

GBP 234.91
1

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit

Ziton ZCR452 Conventional Wireless Dual IO Unit with Battery PackThe ZCR452 is an interface between a conventional fire detection zone and a range of wireless 868 MHz field devices. It provides a method of interfacing a conventional system with a zone of wireless field devices in areas where the installation of system wiring is not an option.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 allows for any compatible conventional fire detection zone to be connected directly to the unit. The ZCR452 in turn provides fire and fault notifications from the wireless field devices to these conventional circuits. In addition any conventional notification circuit may also be wired to the ZCR452 allowing wireless notification devices to be controlled from the conventional notification controller in a similar way to any hardwired conventional notification device.From the conventional interfaces the ZCR452 relays all signals wirelessly to a ZCR868-C wireless cluster communicator that in turn controls a complete zone of wireless detectors remote indicators manual call points inputoutput units andor audio visual or audio visual notification devices. Any abnormalities from the wireless field devices such as faults alarms device removal low battery etc. are relayed back from the cluster communicator to the ZCR452 where they are converted into basic conventional signals that are interpreted by the conventional interface and relayed and displayed on the fire system.The ZCR452 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. Any abnormal battery condition is reported to the fire system.Key FeaturesProvides conventional systems with wireless capabilitiesNo special conventional interfaces requiredFlexible impedance matching for conventional circuitsMonitors all wireless alarm and fault messagesConventional control interface for wireless notification devices and IOTwo way radio communicationFully EN54 compliant and CPR certified

GBP 194.32
1